Comparison of Clinical and Radiological Outcomes Between Different (Balloon) Guide Catheter With and Without Inflated Balloon in Acute Ischemic Stroke Patients: A MaSQ-Registry Study

Author:

Knapen R. R. M. M.ORCID,Celen M.,Pinckaers F. M. E.,Wagemans B. A. J. M.,van Zwam W. H.,van Oostenbrugge R. J.,van der Leij C.

Abstract

Abstract Purpose Balloon guide catheters (BGCs) are used in endovascular treatment (EVT) for ischemic stroke. Previous literature did not distinguish between BGC use with and without inflated balloon. This study aims to compare outcomes between non-BCG and BGC use with and without inflated balloon during EVT. Methods Patients who underwent EVT for anterior circulation ischemic stroke between September 2020 and February 2023 were analyzed. Patients were divided into three groups: non-BGC, BGC with inflated balloon, or BGC without inflated balloon. The primary outcome was the ordinal modified Rankin Scale (mRS) at 90-day follow-up. Secondary outcomes included expanded Thrombolysis In Cerebral Ischemia score (eTICI) and periprocedural complications. Regression analyses with BGC with inflated balloon as comparator were performed with adjustments. Subgroup analyses were conducted based on first-line thrombectomy technique. Results Out of 511 patients, 428 patients were included. Compared to BCG with inflated balloon, the mRS at 90 days did not differ in the group without inflated balloon (adjusted common [ac]OR: 1.07, 95%CI 0.67–1.73) or non-BGC (acOR: 1.42, 95%CI 0.83–2.42). Compared to patients treated with a BGC with inflated balloon, those treated with BGC without inflated balloon had lower eTICI scores (acOR: 0.59, 95%CI 0.37–0.94), and patients treated with non-BGC had lower chances of periprocedural complications (aOR: 0.41, 95%CI 0.20–0.86). Conclusions This study shows no clinical differences in ischemic stroke patients treated with BGC with inflated balloon compared to non-BGC and BGC without inflated balloon, despite lower periprocedural complication rates in the non-BGC group and lower eTICI scores in the BGC without inflated balloon group. Level of Evidence Level 3, non-controlled retrospective cohort study. Graphical Abstract

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ischämischer Schlaganfall: Ballonkatheter beeinflusst klinisches Outcome nicht;Gefäßmedizin Scan - Zeitschrift für Angiologie, Gefäßchirurgie, diagnostische und interventionelle Radiologie;2024-08-27

2. Innovations Lead to Change and State of the Art is Correspondingly Short-Lived: Is There Still a Necessity for Balloon Guide Catheters for Mechanical Thrombectomy in Acute Ischemic Stroke Treatment?;CardioVascular and Interventional Radiology;2024-06-19

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3