Abstract
AbstractFour hot-gas bypass defrosting configurations for CO2-NH3 cascade blast freezer for application in fish processing firm are numerically investigated. Due to the high moisture content of fish, defrosting is necessary after every 4 to 5 h of batch operation. A thermodynamic model for the cascade system and defrosting was developed to study various defrosting configurations formulated by rearranging the existing compressor to operate as a defrosting compressor and with the addition of an external defrosting compressor. From the simulation findings, it can be summarized that the conventional hot-gas bypass defrosting without defrost compressor is suitable for a high-capacity cascade refrigeration system with more than three evaporators. For low cooling capacity refrigeration systems, a defrosting compressor is necessary to elevate the temperature above the cascade condensing temperature. A dedicated defrosting compressor with a power consumption of 3.1 kW and a modified refrigeration/defrosting compressor with a power consumption of 6.8 kW can deliver 33.3 kW of heating at a temperature of +10 °C (45 bar). Incorporating a desuperheater between the main and defrosting compressors reduces compressor temperature and maintains the lubricating oil stability, without change in defrosting energy consumption and less exergy loss. The defrosting efficiency is obtained in the range of 39.7–42% which is in agreement with published literature.
Publisher
Springer Science and Business Media LLC
Reference27 articles.
1. NFBD (2023). National Fisheries Development Board, Department of Fisheries, Ministry of Fisheries, Animal husbandry & Dairying, Govt. of India. Available at: https://nfdb.gov.in/welcome/about_indian_fisheries. viewed on 15/07/2023
2. Pan, M., Zhao, H., Liang, D., Zhu, Y., Liang, Y., & Bao, G. (2020). A review of the cascade refrigeration system. Energies, 13(9). https://doi.org/10.3390/en13092254
3. Bingming, W., Huagen, W., Jianfeng, L., & Ziwen, X. (2009). Experimental investigation on the performance of NH3/CO2 cascade refrigeration system with twin-screw compressor. International Journal of Refrigeration, 32(6), 1358–1365. https://doi.org/10.1016/j.ijrefrig.2009.03.008
4. Lee, T. S., Liu, C. H., & Chen, T. W. (2006). Thermodynamic analysis of optimal condensing temperature of cascade-condenser in CO2/NH3 cascade refrigeration systems. International Journal of Refrigeration, 29(7), 1100–1108. https://doi.org/10.1016/j.ijrefrig.2006.03.003
5. Getu, H. M., & Bansal, P. K. (2008). Thermodynamic analysis of an R744–R717 cascade refrigeration system. International Journal of Refrigeration, 31(1), 45–54. https://doi.org/10.1016/j.ijrefrig.2007.06.014