Author:
Alihosseini Nader,Jahangiri Ali,Ameri Mohammad
Abstract
AbstractIn this paper, the performance of a parallel two-stage compression (PTC) cycle on the domestic refrigerator-freezer in a laboratory according to the IEC 62552–2015 standard is investigated. The relatively large temperature difference between the fresh food compartment (FFC) and the refrigerant in the fresh food compartment evaporator (FFCE) leads to high compression and irreversible losses in the refrigeration circuit. To avoid the mentioned problems and reduce energy consumption, a PTC cycle is used. The innovation of this article is the 4E analyses (energy, exergy, exergoeconomic, exergoenvironmental) for the PTC cycle using the results obtained from the laboratory. Ultimately, the multi-objective optimization of the PTC cycle is conducted. For optimizing the PTC cycle, the total cost rate and the exergy efficiency are set as targets and the evaporator pressure and condenser pressure as variables. MATLAB and REFPROP 9.1 are used to model the system. Results showed that the highest exergy destruction rate is associated with the FFCE (0.349 kW) and compressor (0.183 kW). The highest exergy efficiency among the equipment is evaporators. The maximum exergoeconomic factor is related to the freezer compartment evaporator (FZCE) (98.70%) and then the compressor (98.62%). FZCE has the highest environmental impact (99.9%).
Publisher
Springer Science and Business Media LLC