Simultaneous FET-PET and contrast-enhanced MRI based on hybrid PET/MR improves delineation of tumor spatial biodistribution in gliomas: a biopsy validation study

Author:

Song Shuangshuang,Cheng Ye,Ma Jie,Wang Leiming,Dong Chengyan,Wei Yukui,Xu Geng,An Yang,Qi Zhigang,Lin Qingtang,Lu JieORCID

Abstract

Abstract Purpose Glioma treatment planning requires precise tumor delineation, which is typically performed with contrast-enhanced (CE) MRI. However, CE MRI fails to reflect the entire extent of glioma. O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) PET may detect tumor volumes missed by CE MRI. We investigated the clinical value of simultaneous FET-PET and CE MRI in delineating tumor extent before treatment planning. Guided stereotactic biopsy was used to validate the findings. Methods Conventional MRI and 18F-FET PET were performed simultaneously on a hybrid PET/MR in 33 patients with histopathologically confirmed glioma. Tumor volumes were quantified using a tumor-to-brain ratio ≥ 1.6 (VPET) and a visual threshold (VCE). We visually assessed abnormal areas on FLAIR images and calculated Dice’s coefficient (DSC), overlap volume (OV), discrepancy-PET, and discrepancy-CE. Additionally, several stereotactic biopsy samples were taken from “matched” or “mismatched” FET-PET and CE MRI regions. Results Among 31 patients (93.94%), FET-PET delineated significantly larger tumor volumes than CE MRI (77.84 ± 51.74 cm3 vs. 34.59 ± 27.07 cm3, P < 0.05). Of the 21 biopsy samples obtained from regions with increased FET uptake, all were histopathologically confirmed as glioma tissue or tumor infiltration, whereas only 13 showed enhancement on CE MRI. Among all patients, the spatial similarity between VPET and VCE was low (average DSC 0.56 ± 0.22), while the overlap was high (average OV 0.95 ± 0.08). The discrepancy-CE and discrepancy-PET were lower than 10% in 28 and 0 patients, respectively. Eleven patients showed VPET partially beyond abnormal signal areas on FLAIR images. Conclusion The metabolically active biodistribution of gliomas delineated with FET-PET significantly exceeds tumor volume on CE MRI, and histopathology confirms these findings. Our preliminary results indicate that combining the anatomic and molecular information obtained from conventional MRI and FET-PET would reveal a more accurate glioma extent, which is critical for individualized treatment planning.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3