Author:
Domhagen Fredrik,Wahlgren Paula,Hagentoft Carl-Eric
Abstract
AbstractSome Swedish school buildings built in the 1960s and 1970s experience indoor air quality problems, where the contaminants are suspected to come from the crawl space underneath the building. The poor indoor air quality causes discomfort among pupils and teachers. Installing an exhaust fan to maintain a negative pressure difference in the crawl space relative to indoors or increasing the ventilation in the classroom are two examples of common measures taken to improve the indoor air quality. However, these measures are not always effective, and sometimes the school building has to be demolished. The relation between pressure distribution, contaminant concentration in the classroom, outdoor temperature, wind, mechanical ventilation, and air leakage distribution is complex. A better understanding of these relations is crucial for making decisions on the most efficient measure to improve the indoor air quality. In this paper, a model for contaminant infiltration from the crawl space is used together with the Monte Carlo method to study these relations. Simulations are performed for several cases where different building shapes, building orientations, shielding conditions, and geographical locations are simulated. Results show, for example, that for a building with an imbalanced ventilation system, air is leaking from the crawl space to the classroom for the majority of cases and that concentration levels in the classroom are usually the highest during mild and calm days.
Publisher
Springer Science and Business Media LLC
Subject
Energy (miscellaneous),Building and Construction
Reference16 articles.
1. Airaksinen M, Pasanen P, Kurnitski J, et al. (2004). Microbial contamination of indoor air due to leakages from crawl space: A field study. Indoor Air, 14: 55–64.
2. Annesi-Maesano I, Baiz N, Banerjee S, et al. (2013). Indoor air quality and sources in schools and related health effects. Journal of Toxicology and Environmental Health, Part B, 16: 491–550.
3. Chan W, Joh I, Sherman M (2012). LBNL-5967E. Analysis of air leakage measurements from residential diagnostics database.
4. Dols WS, Polidoro BJ (2015). NIST TN 1887. CONTAM User Guide and Program Documentation Version 3.2. National Institute of Standards and Technology (NIST). Available at https://doi.org/10.6028/NIST.TN.1887.
5. Domhagen F, Wahlgren P, Hagentoft CE (2019). Contaminant transport through the thermal envelope: Evaluation of airflows based on numerical modeling and field measurements. In: Proceedings of the 14th International Conference on Thermal Performance of the Exterior Envelope of Whole Buildings, Clearwater Beach, FL, USA.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献