AbstractAxisymmetric solutions for the bearing capacity of ring foundation resting on anisotropic and heterogenous clays are presented in this paper using finite element analysis (FEA). The NGI-ADP model in PLAXIS FEA, a widely used anisotropic soil model, is adopted to study the stability responses of ring foundations, with special consideration given to the effects of increasing undrained shear strength with the depth. Numerical results are formulated in terms of a dimensionless stability number (bearing capacity ratio) that is a function of three dimensionless input parameters: namely, the ratio of inner and outer radius, the increasing strength gradient ratio, and the anisotropic shear strength ratio. The influence of each dimensionless input parameter on the bearing capacity ratio is investigated using design charts and failure mechanisms, and they are scored by relative importance indexes in multivariate adaptive regression splines (MARS) model—a machine learning approach. A highly accurate equation generated from the MARS model is proposed as an effective tool for engineering practitioners.
Funder
University of Southern Queensland
Publisher
Springer Science and Business Media LLC
Subject
Geology,Soil Science,Geotechnical Engineering and Engineering Geology,Architecture
Reference89 articles.
1. Aamodt MT, Grimstad G and Nordal S (2021). Effect of strength anisotropy on the stability of natural slopes. In: IOP conference series: earth and environmental science, vol 710, no 1. IOP Publishing, p 012025
2. Benmebarek S, Remadna MS, Benmebarek N, Belounar L (2012) Numerical evaluation of the bearing capacity factor of ring footings. Comput Geotech 44:132–138
3. Benmebarek S, Saifi I, Benmebarek N (2017) Undrained vertical bearing capacity factors for ring shallow footings. Geotech Geol Eng 35(1):355–364
4. Beygi M, Keshavarz A, Abbaspour M, Vali R, Saberian M, Li J (2020) Finite element limit analysis of the seismic bearing capacity of strip footing adjacent to excavation in c-φ soil. Geomech Geoeng 17(1):1–14
5. Bhattacharya P (2016) Pullout capacity of strip plate anchor in cohesive sloping ground under undrained condition. Comput Geotech 78:134–143