Minimally invasive reconstruction of acute acromioclavicular joint injuries using the TwinBridge button system

Author:

Balke MauriceORCID,Wafaisade Arasch,Hoeher Juergen,Greshake Oliver

Abstract

Abstract Introduction Acute acromioclavicular joint (ACJ) injuries are among the most common shoulder injuries in active young adults. The most frequently used surgical treatments include the hook plate implantation and arthroscopic treatment using flip-button systems. The aim of this study was to evaluate the results of treating acute ACJ injuries using a new minimally invasive implant based on a flip-button system. Material and methods From January 2016 to October 2019, a total of 20 patients with acute ACJ injuries (1 × Type III, 3 × Type IV, 16 × Type V) underwent surgery using the Twinbridge implant (Smith & Nephew). It is a prefabricated construct consisting of two Endobuttons connected with an UltraTape. One button is placed under the coracoid using a special aiming device and two buttons are placed on the clavicle. Preoperatively, 1 day postoperatively, 3 months and at least 1 year postoperatively, patients were clinically examined and bilateral stress view and axial radiographs were obtained. At final follow-up, the simple shoulder test (SST), Taft score, Constant score, and ACJ instability (ACJI) score were recorded and a side-to-side ratio of the coracoclavicular (CC) distance was calculated. Results All 20 patients were contacted at final follow-up at a mean of 28 (min. 13, max 50) months. Six patients were not willing to come for a clinical and radiographic examination and were contacted via telephone. All six patients were free of complaints. Another two patients free of complaints refused radiographs at final follow-up. The patients presented a mean SST of 99.6% (20 patients, min. 91.7, max. 100), Taft score of 11.6/12 points (12 patients, min. 10, max. 12), ACJI of 85.5/90 points (12 patients, min. 78, max. 90), and a Constant score of 97.1 (14 patients, min. 81.0, max. 100) for the affected shoulder. Preoperative stress view images revealed a mean side-to-side difference of the CC distance with a ratio of 1:2.34 (min. 1:1.80, max. 1:3.33). At final follow-up, CC distance was calculated with a mean ratio of 1:1.12 (min. 1.1, max. 1:1.38). Axial images showed a proper position in all cases. A “perfect” radiological result was achieved in six patients (50%) with a side-to-side CC distance of less than 10% (ratio 1:1.1 or less). A Rockwood type II result was achieved in five patients (42%) with a distance of 10 to 25% (ratio 1.11–1.25). One (8%) presented with a Rockwood type III result with a difference of more than 25% (ratio 1:1.38) and was considered a radiological failure. Conclusions When used correctly, the Twinbridge implant offers good-to-excellent clinical and radiographic results using a minimally invasive surgical technique. Complication rate is comparable to other button-systems.

Funder

Private Universität Witten/Herdecke gGmbH

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3