Abstract
Abstract
Purpose
We investigated bacterial propagation through multifilament, monofilament sutures and whether sutures coated with triclosan would exhibit a different phenomenon.
Methods
One centimetre (cm) wide trenches were cut in the middle of Columbia blood Agar plates. We tested a 6 cm length of two Triclosan-coated (PDS plus®, Vicryl plus®) and two uncoated (PDS ®, Vicryl ®) sutures. Each suture was inoculated with a bacterial suspension containing methicillin-sensitive Staphylococcus aureus (MSSA), Escherichia coli (E. coli), Staphylococcus epidermidis, methicillin-resistant Staphylococcus aureus (MRSA) at one end of each suture. The plates were incubated at 36C for 48 h, followed by room temperature for a further 5 days. We established bacterial propagation by observing for any bacterial growth on the Agar on the opposite side of the trench.
Results
Bacterial propagation was observed on the opposite side of the trench with both suture types, monofilament PDS and multifilament Vicryl, when tested with the motile bacterium (E. coli). Propagation was not observed on the other side of the trench with the monofilament PDS suture following incubation with MSSA and S. epidermidis, and in 66% of MRSA. With multifilament suture Vicryl, propagation was observed on the other side of the trench in 90% (MSSA), 80% (S. epidermidis), and 100% (MRSA) of plates tested. No bacterial propagation was observed in any of the triclosan-coated sutures (monofilament or multifilament).
Conclusions
Monofilament sutures are associated in vitro with less bacterial propagation along their course when compared to multifilament sutures. Inhibition in both sutures can be further enhanced with a triclosan coating.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery