Efficiency of the skeletonized Pendulum K appliance for non-compliance maxillary molar distalization

Author:

Kinzinger Gero Stefan Michael,Hourfar Jan,Lisson Jörg Alexander

Abstract

Abstract Purpose Conventional anchorage with exclusively intraorally anchored appliances for non-compliance molar distalization combines a palatal acrylic button with periodontal anchorage. This type of anchorage is critically discussed because of the temporary hygienic impairment of the palate and the uncertain anchoring quality of the button. A purely dentally/periodontally anchored Pendulum K appliance was developed, which is exclusively anchored via four occlusal rests. The aims of this pilot study were to examine the suitability of the skeletonized Pendulum K for distalization of maxillary molars, and to investigate the quality of this alternative anchoring modality. Patients and methods In all, 10 patients received skeletonized Pendulum K appliances attached to all maxillary premolars for bilateral molar distalization. Supporting anchorage through an acrylic button adjacent to the anterior palate was not used. The pendulum springs were initially activated on both sides with a distalization force of 220 cN each and provided with uprighting and toe-in bends. The specific force/moment system was regularly reactivated intraorally by adjustment of the distal screw. Results The study demonstrates the suitability of the skeletonized Pendulum K appliance for the distalization of maxillary molars (3.28 ± 0.73 mm). Side effects on the molars were slight distal tipping (3.50 ± 2.51°/PP, 3.00 ± 1.41°/SN) and mesial inward rotation (average 2.75 ± 7.50° and 4.50 ± 12.77°). Significant anchorage loss occurred in the form of mesialization of the incisors by 1.40 ± 0.82 mm and of the first premolars by 2.28 ± 0.85 mm. Conclusion The skeletonized Pendulum K appliance allows compliance-free upper molar distalization. Exclusively dental/periodontal anchorage resulted in a lower percentage of molar distalization compared to a conventional anchoring preparation of the Pendulum K with a palatal acrylic button. Anchorage loss had a comparatively stronger effect on the anchoring premolars but less on the incisors. Typical side effects on the molars such as distal tipping and mesial inward rotation were remarkably low.

Funder

Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes

Publisher

Springer Science and Business Media LLC

Subject

Oral Surgery,Orthodontics

Reference31 articles.

1. Angelieri F, Almeida RR, Almeida MR, Fuziy A (2006) Dentoalveolar and skeletal changes associated with the pendulum appliance followed by fixed orthodontic treatment. Am J Orthod Dentofacial Orthop 129:520–527

2. Bussick TJ, McNamara JA Jr. (2000) Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop 117:333–343

3. Byloff FK, Darendeliler MA (1997) Distal molar movement using the pendulum appliance. Part 1: clinical and radiological evaluation. Angle Orthod 67:249–260

4. Byloff FK, Darendeliler MA, Clar E, Darendeliler A (1997) Distal molar movement using the pendulum appliance. Part 2: the effects of maxillary molar root uprighting bends. Angle Orthod 67:261–270

5. Chaques-Asensi J, Kalra V (2001) Effects of the pendulum appliance on the dentofacial complex. J Clin Orthod 35:254–257

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. An Overview of Orthodontic Temporary Anchorage Devices;Clinical Insertion Techniques of Orthodontic Temporary Anchorage Devices;2023-12-18

2. A Simple Technique Using a Modified Nance Appliance as Anchorage for Maxillary Molar Distalization—Two Case Reports;Applied Sciences;2022-01-13

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3