Efficiency of the skeletonized Pendulum K appliance for non-compliance maxillary molar distalization
-
Published:2021-03-02
Issue:6
Volume:82
Page:391-402
-
ISSN:1434-5293
-
Container-title:Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
-
language:en
-
Short-container-title:J Orofac Orthop
Author:
Kinzinger Gero Stefan Michael,Hourfar Jan,Lisson Jörg Alexander
Abstract
Abstract
Purpose
Conventional anchorage with exclusively intraorally anchored appliances for non-compliance molar distalization combines a palatal acrylic button with periodontal anchorage. This type of anchorage is critically discussed because of the temporary hygienic impairment of the palate and the uncertain anchoring quality of the button. A purely dentally/periodontally anchored Pendulum K appliance was developed, which is exclusively anchored via four occlusal rests. The aims of this pilot study were to examine the suitability of the skeletonized Pendulum K for distalization of maxillary molars, and to investigate the quality of this alternative anchoring modality.
Patients and methods
In all, 10 patients received skeletonized Pendulum K appliances attached to all maxillary premolars for bilateral molar distalization. Supporting anchorage through an acrylic button adjacent to the anterior palate was not used. The pendulum springs were initially activated on both sides with a distalization force of 220 cN each and provided with uprighting and toe-in bends. The specific force/moment system was regularly reactivated intraorally by adjustment of the distal screw.
Results
The study demonstrates the suitability of the skeletonized Pendulum K appliance for the distalization of maxillary molars (3.28 ± 0.73 mm). Side effects on the molars were slight distal tipping (3.50 ± 2.51°/PP, 3.00 ± 1.41°/SN) and mesial inward rotation (average 2.75 ± 7.50° and 4.50 ± 12.77°). Significant anchorage loss occurred in the form of mesialization of the incisors by 1.40 ± 0.82 mm and of the first premolars by 2.28 ± 0.85 mm.
Conclusion
The skeletonized Pendulum K appliance allows compliance-free upper molar distalization. Exclusively dental/periodontal anchorage resulted in a lower percentage of molar distalization compared to a conventional anchoring preparation of the Pendulum K with a palatal acrylic button. Anchorage loss had a comparatively stronger effect on the anchoring premolars but less on the incisors. Typical side effects on the molars such as distal tipping and mesial inward rotation were remarkably low.
Funder
Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes
Publisher
Springer Science and Business Media LLC
Subject
Oral Surgery,Orthodontics
Reference31 articles.
1. Angelieri F, Almeida RR, Almeida MR, Fuziy A (2006) Dentoalveolar and skeletal changes associated with the pendulum appliance followed by fixed orthodontic treatment. Am J Orthod Dentofacial Orthop 129:520–527
2. Bussick TJ, McNamara JA Jr. (2000) Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop 117:333–343
3. Byloff FK, Darendeliler MA (1997) Distal molar movement using the pendulum appliance. Part 1: clinical and radiological evaluation. Angle Orthod 67:249–260
4. Byloff FK, Darendeliler MA, Clar E, Darendeliler A (1997) Distal molar movement using the pendulum appliance. Part 2: the effects of maxillary molar root uprighting bends. Angle Orthod 67:261–270
5. Chaques-Asensi J, Kalra V (2001) Effects of the pendulum appliance on the dentofacial complex. J Clin Orthod 35:254–257
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献