Biomechanical Evaluation of Metacarpal Fracture Fixation: Application of a 90° Internal Fixation Model

Author:

Watt Andrew J.,Ching Randal P.1,Huang Jerry I.2

Affiliation:

1. Department of Mechanical Engineering, University of Washington, Seattle, WA, USA

2. Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA, USA

Abstract

Purpose Complications in metacarpal fracture treatment increase in proportion to the severity of the initial injury and the invasiveness of the surgical fixation technique. This manuscript evaluates the feasibility of minimizing internal fixation construct size and soft tissue dissection, while preserving the advantages of stable internal fixation in a biomechanical model. We hypothesized that comparable construct stability could be achieved with mini-plates in an orthogonal (90/90) configuration compared with a standard dorsal plating technique. Methods This hypothesis was evaluated in a transverse metacarpal fracture model. Twelve metacarpals were subject to either placement of a 2.0-mm six-hole dorsal plate or two 1.5-mm four-hole mini-plates in a 90/90 configuration. These constructs were tested to failure in a three-point bending apparatus, attaining failure force, displacement, and stiffness. Results Mean failure force was 353.5±121.1 N for the dorsal plating construct and 358.8±77.1 N for the orthogonal construct. Mean failure displacement was 3.3±1.2 mm for the dorsal plating construct and 4.1±0.9 mm for the orthogonal construct. Mean stiffness was 161.3±50.0 N/mm for the dorsal plating construct and 122.1±46.6 N/mm for the orthogonal construct. Mean failure moment was 3.09±1.06 Nm for the dorsal plating construct and 3.14±0.67 Nm for the orthogonal construct. The dorsal plating group failed via screw pullout, whereas the orthogonal failed either by screw pullout or breakage of the plate. Conclusions When subject to apex dorsal bending, the orthogonal construct and the standard dorsal plate construct behaved comparably. These data suggest that despite its shorter length, lower profile, and less substantial screws, the orthogonal construct provides sufficient rigidity. Clinical Relevance This study represents a “proof of concept” regarding the applicability of orthogonal plating in the metacarpal and provides the foundation for minimizing construct size and profile.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3