Affiliation:
1. Department of Orthopaedic Surgery, Gifu Prefectural General Medical Center, Gifu 500-8717, Japan
Abstract
This report describes two cases of traumatic closed index extensor tendon rupture at the musclotendinous junction. Both patients were injured when their work gloves were caught in the revolving parts of machines, and both were treated surgically. One of the patients completely ruptured the index extensor digitorum communis (EDC) and the extensor indicis proprius (EIP) tendons at the musclotendinous junction of dorsal forearm. In this patient, the distal stump of the index EDC tendon was sutured to the middle EDC tendon in an end-to-side juncture. The other patient completely ruptured the EIP tendon and partially ruptured the index EDC tendon at the musclotendinous junction. In this patient, tendon transfer of the extensor digiti minimi (EDM) to the EIP tendon and plication of the index EDC tendon were performed. In both cases, surgical intervention enabled the patients to extend their index fingers almost normally; however, the former complained of inability to extend his index finger independently. Tendon transfer of the EDM in cases of index extensor tendon rupture at the musclotendinous junction is a good method to restore ability to independently extend the index finger. However, consideration should be given to anatomical variation in the little finger. The EDC tendon is sometimes absent leaving the EDM tendon as the only extensor tendon to the little finger.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献