Radiographic Evaluation of Dorsal Screw Penetration after Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study

Author:

Maschke Steven D.,Evans Peter J.1,Schub David2,Drake Richard3,Lawton Jeffrey N.1

Affiliation:

1. Section of Hand & Upper Extremity Surgery, Department of Orthopedic Surgery, Cleveland Clinic, 9500 Euclid Avenue A40, Cleveland, OH 44195, USA

2. Case Western Reserve, University School of Medicine, Cleveland, OH, USA

3. Lerner College of Medicine, NA24, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA

Abstract

Introduction Extensor tendon irritation and attritional tendon ruptures are potentially serious complications after open reduction and internal fixation of distal radius fractures. These complications are well recognized after dorsal plating of distal radii; and these are now being reported after errant screw placement during volar fixed-angle plating. Intraoperative detection of improper screw placement is critical, as corrective action can be taken before completion of the operative procedure. The purpose of this study was to define the extensor tendon compartments at risk secondary to dorsal screw penetration and to compare pronation and supination fluoroscopic images with standard lateral images in demonstrating dorsal screw prominence during volar locked plating. Methods Eight fresh-frozen human cadaveric upper extremities underwent fixation with a volar, fixed-angle distal radius locked plate (Wright Medical Technology, Arlington, TN). Three fluoroscopic views (lateral, supinated, and pronated) followed by dorsal wrist dissections were compared to determine accuracy in detecting dorsal screw prominence and extensor tendon compartment violation. Subsequently, screws measuring 2, 4, 6, 8, and 10(mm longer than the measured depths were sequentially inserted into each distal locking screw, with each image deemed either “in” (completely inside the bone) or “out” (prominent screw tip dorsally-would typically be exchanged for a shorter screw intraoperatively). Results The radial most distal locking screw (position 1) violated either the first (25%) or second (75%) extensor tendon compartments. The average screw prominence required for radiographic detection was: 6.5(mm for lateral views and 2(mm for supinated views. Pronated views did not identify prominent screws. Screws occupying plate position 2 consistently entered Lister's tubercle, with 5/8 exiting the apex and 3/8 exiting the radial base. The average screw prominences for radiographic detection were: 2.75(mm-lateral views and 3.0(mm-supinated views. Although the screws entered the second dorsal compartment, they did not encroach upon either of the tendons. Screws occupying plate position 3 violated the third extensor tendon compartment in 7/8 specimens with 1/8 exiting the Ulan base of Lister's tubercle. The average screw prominences for radiographic detection were: 3.5 (mm-lateral views and 2.5(mm-pronated views. Supinated views did not identify prominent hardware. Screws occupying plate position 4 all violated the IV dorsal extensor compartment-2/8 screws were noted to tent the posterior interosseous nerve. The average screw prominences required for radiographic detection were: 4.0(mm-lateral views and 2.5(mm-pronated views. The supinated views did not identify prominent screws. Conclusions Volar fixed-angle plating has shown great promise in the advancement of distal radius fracture management. We have seen in our referral practices and in the literature an increase in the number of extensor tendon complications arising from unrecognized dorsally prominent screws, pegs, or tines. Standard PA and lateral radiographs cannot adequately visualize screw position and length secondary to the complex geometry of the dorsal cortex. We believe this study supports the routine application of intraoperative, oblique pronosupination fluoroscopic imaging for enhanced confirmation of distal locking screw position and length.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 88 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370