Increased crystalloid fluid requirements during zone 3 Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) versus Abdominal Aortic and Junctional Tourniquet (AAJT) after class II hemorrhage in swine

Author:

Brännström AndreasORCID,Dahlquist Albin,Gustavsson Jenny,Arborelius Ulf P.,Günther Mattias

Abstract

Abstract Purpose Pelvic and lower junctional hemorrhage result in a significant amount of trauma related deaths in military and rural civilian environments. The Abdominal Aortic and Junctional Tourniquet (AAJT) and infra-renal (zone 3) Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) are two options for resuscitation of patients with life threatening blood loss from and distal to the pelvis. Evidence suggest differences in the hemodynamic response between AAJT and zone 3 REBOA, but fluid management during resuscitation with the devices has not been fully elucidated. We compared crystalloid fluid requirements (Ringer’s acetate) between these devices to maintain a carotid mean arterial pressure (MAP) > 60 mmHg. Methods 60 kg anesthetized and mechanically ventilated male pigs were subjected to a mean 1030 (range 900–1246) mL (25% of estimated total blood volume, class II) haemorrhage. AAJT (n = 6) or zone 3 REBOA (n = 6) were then applied for 240 min. Crystalloid fluids were administered to maintain carotid MAP. The animals were monitored for 30 min after reperfusion. Results Cumulative resuscitative fluid requirements increased 7.2 times (mean difference 2079 mL; 95% CI 627–3530 mL) in zone 3 REBOA (mean 2412; range 800–4871 mL) compared to AAJT (mean 333; range 0–1000 mL) to maintain target carotid MAP. Release of the AAJT required vasopressor support with norepinephrine infusion for a mean 9.6 min (0.1 µg/kg/min), while REBOA release required no vasopressor support. Conclusion Zone 3 REBOA required 7.2 times more crystalloids to maintain the targeted MAP. The AAJT may therefore be considered in a situation of hemorrhagic shock to limit the need for crystalloid infusions, although removal of the AAJT caused more severe hemodynamic and metabolic effects which required vasopressor support.

Funder

Karolinska Institute

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine,Orthopedics and Sports Medicine,Emergency Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3