Newtonian (moving mass) calibration of tilt and gravity meters and the investigation of some factors influencing its accuracy

Author:

Papp Gábor,István Csáki Dániel,Benedek JuditORCID

Abstract

AbstractThe idea of moving mass calibration (MMC) of relative gravity meters dates back to the seventies of the last century. Probably the MMC apparatus built in the underground Mátyáshegy Gravity and Geodynamics Laboratory Budapest has been used most extensively and several spring type instruments (LaCoste and Romberg and Scintrex) have been investigated and calibrated by it. Its test mass is a cylindrical ring having a weight of 3 tons. Its main advantage is simplicity in terms of metrology. The same principle and technology can be used to test compact tilt sensors having nanoradian resolution capability. Up to now rigorous testing methods below microradian range were not available in practice. The analysis of the so-called off-axis variation of the gravitational vector generated by the vertical movement of the cylindrical ring mass of the Mátyáshegy MMC device, however, showed that a sufficiently accurate reference signal having (15 ± 0.02) nrad peak-to-peak amplitude can be provided for calibration. It is just in the range of tilt induced by earth tide effect, which is a “standard” signal component in the time series recorded in observatory environment. In the first part of the paper, a discussion of the proposed methodology of tilt meter calibration is given. Then the analysis of the effect of volumetric discretization of the cylindrical ring on the accuracy of calibration is provided. Finally, possible material inhomogeneities of the ring mass and their gravitational effects are investigated by forward simulations and inversion. For this purpose the results of 300 gravimeter calibration experiments, analysed and published earlier, were utilized.

Funder

NKFIH OTKA

Publisher

Springer Science and Business Media LLC

Subject

Computers in Earth Sciences,Geochemistry and Petrology,Geophysics

Reference19 articles.

1. Achilli V, Baldi P, Casula G (1995) A calibration system for superconducting gravimeters Bull. Géodésique 69:73–80. https://doi.org/10.1007/BF00819553

2. Barta GY, Hajósy A, Varga P (1986) Possibilities for the absolute calibration of recording gravimeters. Proc. of the Xth Int. Symp. on Earth Tides September 23–28, 1985 Madrid, Spain: with special sessions dedicated to ocean tides, in Vieira R, Consejo superior de investigaciones cientificas (CSIC), Madrid 27–34

3. Benedek J (2016) Synthetic modelling of the gravitational field, Publications in Geomatics, 19, 7 – 106. http://geomatika.ggki.hu/kozlemenyek/public/files/homepage/GK_XIX_1_honlap.pdf

4. Benedek J, Papp G, Kalmar J (2018) Generalization techniques to reduce the number of volume elements for terrain effect calculations in fully analytical gravitational modelling. J Geodesy 92(4):361–381. https://doi.org/10.1007/s00190-017-1067-1

5. Csapó G, Szatmári G (1995) Apparatus for moving mass calibration of LaCoste–Romberg feedback gravimeters. Metrologia 32:225–230. https://doi.org/10.1088/0026-1394/32/3/011