Abstract
Abstract
Purpose
In this study, a three-step novel surgical technique was developed for incisional hernia, in which a laparoscopic procedure with a mini-laparotomy is combined: so-called ‘three-step incisional hybrid repair’. The aim of this study was to reduce the risk of intestinal lacerations during adhesiolysis and recurrence rate by better symmetrical overlap placement of the mesh.
Objectives
To evaluate first perioperative outcomes with this technique.
Methods
From 2016 to 2020, 70 patients (65.7% females) with an incisional hernia of > 2 and ≤ 10 cm underwent a elective three-step incisional hybrid repair in two non-academic hospitals performed by two surgeons specialised in abdominal wall surgery. Intra- and postoperative complications, operation time, hospitalisation time and hernia recurrence were assessed.
Results
Mean operation time was 100 min. Mean hernia size was 4.8 cm; 45 patients (64.3%) had a hernia of 1–5 cm, 25 patients (35.7%) of 6–10 cm. Eight patients had a grade 1 complication (11.4%), five patients a grade 2 (7.1%), two patients (2.8%) a grade 4 complication and one patient (1.4%) a grade 5 complication. Five patients had an intraoperative complication (7.0%), two enterotomies, one serosa injury, one omentum bleeding and one laceration of an epigastric vessel. Mean length of stay was 3.3 days. Four patients (5.6%) developed a hernia recurrence during a mean follow-up of 19.5 weeks.
Conclusion
A three-step hybrid incisional hernia repair is a safe alternative for incisional hernia repair. Intraoperative complications rate was low.
Publisher
Springer Science and Business Media LLC
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献