Health and safety control measures and MR quality control results in the MRI units of two public hospitals within the Mangaung metropolitan

Author:

Rathebe Phoka C.ORCID

Abstract

AbstractThis study aimed to identify risks and hazards in the magnetic resonance imaging (MRI) units, and assess the quality compliance of the scanners within two public hospitals in Mangaung. This is a follow-up study from a previously published study that measured static magnetic fields and radiofrequency magnetic fields in the MRI units included here. An observational checklist was used to identify risks and hazards which were later fed into a baseline risk assessment to classify and review existing control measures in the MRI units of hospitals A and B. The availability of MRI Health and Safety measures were benchmarked against the latest American College of Radiology (ACR) MRI safety requirements. The probability of risk occurrence and severity of hazards were assigned a score ranging from improbable (1) to very likely (5) and minimal (1) to irreversible effect (5). The weekly quality control test results obtained from both units were measured against the ACR quality control acceptable criteria. Similar risks were observed in both MRI units but the multiplication of probability and consequence in all risk categories resulted in a moderate risk-rating score of 12.3 for hospital A and 13.1 for hospital B. Lack of demarcation of four MRI safety zones, ferromagnetic detectors, 5-gauss line, and access control in both units scored above 15 and were classified as high risk. The defective air-cooling systems influenced the temperature of the scanner room, which affected the apparent diffusion coefficient (ADC) measurements performed from 1.5 T Siemens. On a 3.0 T Philips, a low contrast object detectability had 29 spokes for ACR T2, while the percent integral uniformity for image intensity uniformity was 78.2 %. High and moderate risks observed in both units could be reduced by the implementation of an effective health and safety programme. The ambient temperature within the scanner room should be maintained at 21 °C to attain well-performing ADC measurements and RF subsystems should be visually inspected and maintained regularly to obtain optimal image quality.

Publisher

Springer Science and Business Media LLC

Subject

General Earth and Planetary Sciences,General Physics and Astronomy,General Engineering,General Environmental Science,General Materials Science,General Chemical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3