Abstract
AbstractThe present study proposes a new technique for diagnosing the Inter-Turn Stator-Winding fault in Permanent Magnet Synchronous Motors. Under faulty operating conditions, the system’s model is built while considering specific parameters linked to fault location and sharpness. The proposed fault-detection method is principally based on the Power Spectral Density estimator’s association with the Support Vector Machine. This classifier is used to separate different regions of system performance. It has been trained to associate the Power Spectral Density current’s magnitude and the stator’s current negative sequence with the fault severity. This method has shown exceptional performance as long as it achieves a fault detection rate of 98.5% for different fault severities. Two Power Spectral Density estimators were compared in terms of their ability to extract fault characteristics, namely Burg’s method and Welch’s method. It was concluded from this study that Welch’s has a higher frequency resolution than Burg’s method.
Publisher
Springer Science and Business Media LLC
Subject
General Earth and Planetary Sciences,General Physics and Astronomy,General Engineering,General Environmental Science,General Materials Science,General Chemical Engineering
Reference18 articles.
1. Yildirim M, Polat M, Kurum H (2014) A survey on comparison of electric motor types and drives used for electric vehicles. In: 16th International Power Electronics and Motion Control Conference. Expo. PEMC, pp 218–223
2. Vaseghi B, Takorabet N (2008) Experimentally validated dynamic fault model for PMSM with stator winding inter-turn fault. UMR 7037:1–5
3. Choi J, Gu B, Won C (2013) J Electr Eng Technol. Modeling and analysis of PMSMs under inter turn short faults 8(5):1243–1250
4. Ludwinek K (2014) Influence of DC voltage and current of field winding on induced stator voltages of a salient pole synchronous generator. Int Rev Electr Eng 9(1):62–72
5. Tallam RM, Habetler TG, Harley RG (2002) Transient model for induction machines with stator winding turn faults. IEEE Trans Ind Appl 38(3):632–637
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献