Evaluating the influence of 6 MV and 15 MV photon beams on prostate intensity-modulated radiation therapy plans

Author:

El Gendy Reham A.1,Attalla Ehab M.2,Elkerm Yasser M.3,Alfarrash Ali4

Affiliation:

1. Ayadi Al Mostakbl Oncology Center, Alexandria, Egypt

2. National Cancer Institute, Cairo University, Cairo, Egypt

3. Cancer Management and Research Department, Medical Research Institute, Alexandria University, Alexandria, Egypt

4. Faculty of Science, Mansoura University, Mansoura, Egypt

Abstract

Abstract Objective We aimed to determine the effects of low- and high-energy intensity-modulated radiation therapy (IMRT) photon beams on the target volume planning and on the critical organs in the case of prostate cancer. Methods Thirty plans were generated by using either 6 MV or 15 MV beams separately, and a combination of both 6 and 15 MV beams. All plans were generated by using suitable planning objectives and dose constraints, which were identical across the plans, except the beam energy. The plans were analyzed in terms of their target coverage, conformity, and homogeneity, regardless of the beam energy. Results The mean percentage values of V70 Gy for the rectal wall for the plans with 6 MV, 15 MV, and mixedenergy beams were 16.9%, 17.8%, and 16.4%, respectively, while the mean percentage values of V40 Gy were 53.6%, 52.3%, and 50.4%. The mean dose values to the femoral heads for the 6 MV, 15 MV, and mixed-energy plans were 30.1 Gy, 25.5 Gy, and 25.4 Gy, respectively. The mean integral dose for the 6 MV plans was 10% larger than those for the 15 MV and mixed-energy plans. Conclusion These preliminary results suggest that mixed-energy IMRT plans may be advantageous with respect to the dosimetric characteristics of low- and high-energy beams. Although the reduction of dose to the organs at risk may not be clinically relevant, in this study, IMRT plans using mixed-energy beams exhibited better OAR sparing and overall higher plan quality for deep-seated tumors.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference25 articles.

1. The dosimetric effects of different beam energy on physical dose distributions in IMRT based on analysis of physical indices;Ismail;J Cancer Therapy,2013

2. Dosimetric impact of mixed-energy volumetric modulated arc therapy plans for high-risk prostate cancer;Pokharel;Int J Cancer Ther Oncol,2013

3. The dosimetric effect of mixed-energy IMRT plans for prostate cancer;Jong Min;J Appl Clin Med Phys,2011

4. An analysis of 6-MV versus 18-MV photon energy plans for intensity-modulated radiation therapy (IMRT) of lung cancer;Elisabeth;Radiother Oncol,2007

5. The effect of 6 and 15 MV on intensity-modulated radiation therapy prostate cancer treatment: plan evaluation, tumour control probability and normal tissue complication probability analysis, and the theoretical risk of secondary induced malignancies;Hussein;Br Radiol,2012