Cine magnetic resonance imaging for quantitative assessment of healthy volunteers and patients with organic small bowel disease ⁎

Author:

Wang Zi,Tang Hao,Li Jianjun,Wang Qiuxia,Shen Yaqi,Li Zhen,Yuan Sishu,Hu Daoyu

Abstract

Abstract Objective The aim of the study was to use dynamic magnetic resonance imaging (MRI) to compare quantitative parameters of small bowel motility between healthy volunteers and patients with small bowel diseases in order to investigate the characteristics of normal and impaired bowel peristalsis. Methods A total of 44 healthy volunteers (20 men, 24 women; mean age: 36 years; range: 20-61 years) and 42 patients (28 men, 14 women; mean age: 44 years; range: 15-72 years) with organic small bowel disease were recruited in our hospital (Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China) in this prospective study approved by the hospital institutional review board. Imaging was performed using a 3.0-T scanner 45 minutes after standardized oral administration of 1500 mL non-absorbable fluid (2.5% mannitol). A serial coronal scan was performed at selected planes for two minutes without breath-hold. Time-caliber curves were plotted at two well-distended small bowel loops in both healthy and patient groups regardless of location. Luminal diameter (LD), contraction period (CP), frequency of contraction (FC), and amplitude-diameter ratio (ADR) were measured based on the graph. Results The characteristics of abnormal peristaltic parameters were assessed in different patients and compared to normal curves from healthy volunteers. A total of 37 segments with abnormal motility were confirmed by two readers in consensus, based on curve patterns and the presence of a stationary phase. Compared to normal peristalsis in healthy volunteers, five different patterns of impaired peristalsis were identified: I, consecutive; II, slow; III, giant type; IV, uncoordinated; and V, akinetic. Dilated LDs were detected in all instances of abnormal peristalsis (P < 0.05). Increased frequency was found in type I [(8.73 ± 1.15) /min], while decreased frequency was detected in type III peristalsis [(0.67 ± 0.29) /min]. There were no significant differences in frequency between type II [(3.19 ± 0.43) /min] and normal peristalsis [(3.45 ± 0.57) /min]. Apart from type I [(8.70 ± 0.75) /min], increased FCs were found in all other abnormal patterns. In type II peristalsis, the average ADR value was 0.82 ± 0.08, comparable to the ADR value in the healthy group (0.83 ± 0.13). Conclusion MR cine is an effective method for differentiating normal and abnormal small bowel peristalsis. Plotting time-caliber curves and measuring quantitative MR cine parameters such as LD, CP, FC, and ADR offers more precise information about small bowel motility.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3