A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment

Author:

Wagdy Ali1,EI Shahat Khaled2,Ashry Huda3,El Shershaby Amaal4,Abdo Ehab2

Affiliation:

1. Al Galaa Oncology Center, Egypt

2. Clinical Oncology Department-Faculty of Medicine-Al Azhar University, Cairo, Egypt

3. National Center for Radiation Research and Technology-AEA, Egypt

4. Physics Department Women College for Arts Science and Education-Ain Sham University, Cairo,Egypt

Abstract

AbstractFlattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differences with respect to standard flattening filter (FF) beams, such that the generally used dosimetric parameters and definitions are not always viable. This study investigates dosimetric parameters for use in the quality assurance of FFF beams generated by medical linacs in radiotherapy. The main characteristics of the photon beams are analyzed using specific data generated by a Varian TrueBeam linac having both FFF and FF beams of 6 and 10 MV (megavolt) energy, respectively. Definitions for dose profile parameters are suggested, starting from the renormalization of the FFF with respect to the corresponding FF beam. From this point, the flatness concept is translated into one of “un-flatness”, and other definitions are proposed, maintaining a strict parallelism between FFF and FF parameter concepts. The quality controls used in establishing a quality assurance program when introducing FFF beams into the clinical environment are given, maintaining similarity to those used for standard FF beams, and recommendations for the introduction of FFF beams into clinical radiotherapy application for breast cancer patients are provided as an example for comparison between FFF and FF for dose distribution and coverage for a target volume. Although there are many advantages of using a FFF beam, especially for advanced radiotherapy techniques, there are a few limitations (e.g., using a relatively higher energy photon beam for stereotactic radiotherapy (SRT), limited speed of current multileaf collimators (MLCs), and off-axis distance-dependent modulation in intensity-modulated radiation therapy (IMRT)) as well as challenges (e.g., criteria for beam quality evaluation and penumbra, establishment of dosimetry methods, and consequences of photon target burn-up) that need to be addressed for establishing the FFF beam as a viable alternative to the FF beam.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference16 articles.

1. Monte Carlo study of photon fields from a flattening filter-free clinical accelerator;Med Phys,2006

2. Properties of un-flattened photon beams shaped by a multileaf collimator;Med Phys,2006

3. The characterization of unflattened photon beams from a 6 MV linear accelerator;Phys Med Biol,2008

4. Consequences of removing the flattening filter from LINACs in generating high dose rate photon beams for clinical applications: A Monte Carlo study verified by measurement. NuclInstrum;Methods Phys Res B,2007

5. Dosimetric characteristics of 6 and 10MV unflattened photon beams;Radiother Oncol,2009