Author:
Vogel Christian,Hoffmann Marie C.,Krüger Oliver,Murzin Vadim,Caliebe Wolfgang,Adam Christian
Abstract
AbstractPhosphorus (P) fertilizers from secondary resources became increasingly important in the last years. However, these novel P-fertilizers can also contain toxic pollutants such as chromium in its hexavalent state (Cr(VI)). This hazardous form of chromium is therefore regulated with low limit values for agricultural products even though the correct determination of Cr(VI) in these fertilizers may be hampered by redox processes, leading to false results. Thus, we applied the novel diffusive gradients in thin-films (DGT) technique for Cr(VI) in fertilizers and compared the results with the standard wet chemical extraction method (German norm DIN EN 15192) and Cr K-edge X-ray absorption near-edge structure (XANES) spectroscopy. We determined an overall good correlation between the wet chemical extraction and the DGT method. DGT was very sensitive and for most tested materials selective for the analysis of Cr(VI) in P-fertilizers. However, hardly soluble Cr(VI) compounds cannot be detected with the DGT method since only mobile Cr(VI) is analyzed. Furthermore, Cr K-edge XANES spectroscopy showed that the DGT binding layer also adsorbs small amounts of mobile Cr(III) so that Cr(VI) values are overestimated. Since certain types of the P-fertilizers contain mobile Cr(III) or partly immobile Cr(VI), it is necessary to optimize the DGT binding layers to avoid aforementioned over- or underestimation. Furthermore, our investigations showed that the Cr K-edge XANES spectroscopy technique is unsuitable to determine small amounts of Cr(VI) in fertilizers (below approx. 1% of Cr(VI) in relation to total Cr).
Funder
Deutsche Forschungsgemeinschaft
Bundesministerium für Bildung und Forschung
Publisher
Springer Science and Business Media LLC
Subject
Health, Toxicology and Mutagenesis,Pollution,Environmental Chemistry,General Medicine
Reference21 articles.
1. Bajt S, Clark SB, Sutton SR, Rivers ML, Smith JV (1993) Synchrotron X-ray microprobe determination of chromate content using X-ray absorption near-edge structure. Anal Chem 65:1800–1804
2. Caliebe W, Murzin V, Kalinko A, Görlitz M (2019) High-flux XAFS-beamline P64 at PETRAIII. AIP Conf Proc 2054:060031
3. Davison W (2016) Diffusive gradients in thin-films for environmental measurements. Cambridge University Press, Cambridge
4. DIN EN 15192, (2006). Characterization of waste and soil – determination of Cr(VI) in solid material by alkaline digestion and ion chromatography with spectrometric detection
5. EU, (2017). Communication from the Commission to the European Parliament, the Council, the European economic and social committee and the committee of the regions on the 2017 list of Critical Raw Materials for the EU
Cited by
23 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献