Abstract
AbstractIn this study, timber column–sill joints strengthened with carbon fiber-reinforced plastic (CFRP) plates using bonds and screws were subjected to loading tests. Twelve joint specifications were considered depending on different combinations of the CFRP plate surface finish and thickness and the type of bond, and the corresponding effects on the load–displacement behavior of the joints were investigated. Three failure modes were observed in addition to the peeling of the CFRP plate. The specimens that failed owing to screw tear out and screw head pull-through in the CFRP plate or splitting of the sill showed load–displacement curves of a similar shape. Those that failed owing to buckling of the CFRP plate showed a rapid and substantial load decrease due to failure. This failure mode was only observed in 0.50 mm thick CFRP plate specimens. When a peel-ply CFRP plate was installed in the column–sill joint specimens, similar secant stiffnesses were observed in the silicon and epoxy resin-bonded specimens, both with high shear strength. Although the specimens with bonds with a high shear strength showed lower deformation performance, the specimens' maximum load increased with the bond's shear strength. The maximum load improved for a 0.75 mm thick peel-ply silicon- or epoxy-bonded CFRP plate. The load's maximum value after peeling the CFRP plate was 0.79–1.23 times as large as the maximum load of the no-bond specimens and did not change significantly.
Funder
Tokyo Metropolitan Small and Medium Enterprise Support Center
Publisher
Springer Science and Business Media LLC
Subject
Civil and Structural Engineering,Geotechnical Engineering and Engineering Geology
Reference28 articles.
1. Japan Building Disaster Prevention Association (2011) Revision for 2010 Guide for design and construction of aseismic retrofitting of existing reinforced concrete construction utilizing continuous carbon fiber reinforcement material (in Japanese)
2. American Concrete Institute (2008) Guide for design and construction of externally bonded frp systems for strengthening concrete structures
3. Consiglio Nazionale delle Ricerche (2006) Guide for the design and construction of externally bonded FRP systems for strengthening existing structures
4. Cao S, Chen J, Pan J, Sun N (2007) ESPI measurement of bond–slip relationships of FRP–concrete interface. J Compos Constr 11(2):149–160
5. Mazzotti C, Savoia M, Ferracuti B (2008) An experimental study on delamination of FRP plates bonded to concrete. Constr Build Mater 22(7):1409–1421