Early Complications After Percutaneous Closure of Atrial Septal Defect in Infants with Procedural Weight Less than 15 kg

Author:

Tanghöj GustafORCID,Odermarsky Michal,Naumburg Estelle,Liuba Petru

Abstract

AbstractAtrial septal defect (ASD) is the most common congenital cardiac lesion accounting for 10–15% of all cardiac malformations. In the majority of cases, the secundum type of the ASD is closed percutaneously in the catheterization laboratory. Although transcatheter closure of ASD is considered safe and effective in pediatric patients, there are limited data regarding the efficacy and safety of device ASD closure in smaller infants. The aim of this study was to determine risk of complications within 72 h following device closure of ASD in children of body weight <15 kg compared to larger children. Overall 252 children who underwent transcatheter closure of ASD at Children’s Heart Centre in Lund, Sweden, between 1998 and 2015 were included. Data regarding demographics, comorbidity and complications occurring during and after device procedure until discharge were retrieved from the hospital’s databases. Echocardiographic data were obtained from the digital and videotape recordings. Nearly half of the study cohort (n = 112; 44%) had a procedural weight <15 (median 11.3) kg with a median procedural age of 2.02 years. Among this study group, 22 (9%) children had post-procedural in-hospital complications, of which 16 (7%) were considered as major and six (2%) considered as minor. No deaths occurred. There was no significant difference in of the occurrence of major or minor complications between the two groups (p = 0.32). Larger ASD was more often associated with minor complications, OR 1.37 (95% CI 0.99–1.89), which most often consisted of transient arrhythmias during or after the procedure. Percutaneous ASD device closure can be performed safely in low-weight infants with a risk of post-procedural in-hospital complications comparable to larger/older children. Nevertheless, careful considerations of the indications to device closure is needed, particularly in children with larger ASD, as recommended by the current international guidelines for ASD closure.

Funder

Department of Clinical Science, Unit of Research, Education and Development - Östersund, Umeå University

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3