Author:
Alsaffar Ammar,Sun Kaicong,Simon Sven
Abstract
AbstractBeam hardening (BH) is one of the major artifacts that severely reduces the quality of computed tomography (CT) imaging. This BH artifact arises due to the polychromatic nature of the X-ray source and causes cupping and streak artifacts. This work aims to propose a fast and accurate BH correction method that requires no prior knowledge of the materials and corrects first and higher-order BH artifacts. This is achieved by performing a wide sweep of the material based on an experimentally measured look-up table to obtain the closest estimate of the material. Then, the non-linearity effect of the BH is corrected by adding the difference between the estimated monochromatic and the polychromatic simulated projections of the segmented image. The estimated polychromatic projection is accurately derived using the least square estimation (LSE) method by minimizing the difference between the experimental projection and the linear combination of simulated polychromatic projections. As a result, an accurate non-linearity correction term is derived that leads to an accurate BH correction result. The simulated projections in this work are performed using a multi-GPU-accelerated forward projection model which ensures a fast BH correction in near real-time. To evaluate the proposed BH correction method, we have conducted extensive experiments on real-world CT data. It is shown that the proposed method results in images with improved contrast-to-noise ratio (CNR) in comparison to the images corrected from only the scatter artifacts and the BH-corrected images using the state-of-the-art empirical BH correction method.
Funder
Deutscher Akademischer Austauschdienst
Deutsche Forschungsgemeinschaft
Universität Stuttgart
Publisher
Springer Science and Business Media LLC
Reference41 articles.
1. Boas, F., et al.: Computed tomography artifacts: causes and reduction techniques. Imaging Med. 4(2), 229–240 (2012)
2. Gompel, G., et al.: Iterative correction of beam hardening artifacts in CT. Phys. Med. Biol. 38(7), s36 (2011)
3. Krumm, M., et al.: Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomography. NDT and E Int. 41(4), 242–251 (2008)
4. Brooks, R., et al.: Beam hardening in X-ray reconstructive tomography. Phys. Med. Biol. 21(3), 390–398 (1976)
5. McDavid, W., et al.: Correction for spectral artifacts in cross-sectional reconstruction from X-rays. Med. Phys. 4(1), 54–57 (1997)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. A CBCT Beam-hardening Artifact Correction Method based on Optimal Filter Material Selection;2024 5th International Conference on Mechatronics Technology and Intelligent Manufacturing (ICMTIM);2024-04-26
2. GPU-accelerated polyenergetic forward projection for 9 MeV industrial CT system;Insight - Non-Destructive Testing and Condition Monitoring;2023-12-01