Abstract
AbstractThis study aims to test the hypothesis that the effect of excimer laser coronary angioplasty (ELCA) not only vaporizes thrombi and their underlying coronary plaque, it also changes their quality. We performed a series of cross-sectional analyses in 52 lesions in 51 patients before and after ELCA with integrated backscatter-intravascular ultrasound (IB-IVUS). The constituent parts of the plaque can be assessed by IB-IVUS (i.e., calcified, fibrous, lipid) according to integrated backscatter values. Minimum lumen diameter, lumen volume and vessel volume expanded after ELCA, while plaque volume did not significantly decrease. There was also a decrease of ‘lipid’ component (35.4–30.3%, P < 0.001) and an increase of IB-IVUS-derived ‘fibrous’ part (34.5–38.3%, P < 0.001). These results may help in understanding plaque change after ELCA. Excimer laser coronary angioplasty seems to contribute to the modification of coronary plaque composition in addition to debulking it.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献