Seismic performance of existing water tank after condition ranking using non-destructive testing

Author:

Nayak Chittaranjan B.,Thakare Sunil B.

Abstract

Abstract There has been a collaborative attempt to address the seismic vulnerability of existing structures in India after an earthquake in Bhuj, Gujarat, in 2001. Seismic diagnosis and seismic retrofit for the existing tanks have become a remarkable issue to be worked since deterioration is a cosmopolitan and natural phenomenon. It is important to know the exact reason for distress and type of distress. To manage such issues, a proper method of repair and rehabilitation with detailed plans and methodology is required. This paper is aimed at evolving systematic investigation metrology for condition ranking procedure based on the analytical hierarchy process (AHP) and strengthening by various retrofitting strategies. For that case study, an existing elevated water tank is considered, which was designed according to state of the art over 40 years ago as per old Indian Standard (IS) code. The ranking assessment of the elevated service reservoir was carried out using different non-destructive tests (NDTs). DER, i.e., degree (D), extent (E) and relevancy (R) rating technique was employed to find out the condition index of the elevated service reservoir (ESR). After finding the condition ranking of the existing structure, an analysis was carried out using SAP 2000 to find the present-day seismic requirements using IS codes. After knowing the seismic demand of the water tank, various retrofitting methods were adopted for improving the drift capacity and flexural capacity of the structure. The results were finally used to address some of the critical issues of the seismic response of the retrofitted structure in terms of a time period, mode shapes, base shear, displacement, acceleration, and velocity. From the case study result of seismic retrofit for the existing elevated water tank, it is confirmed that a relatively simple seismic retrofit method is effective to keep the tank functional after an earthquake.

Publisher

Springer Science and Business Media LLC

Subject

Civil and Structural Engineering

Reference33 articles.

1. Alireza H (2015) Types of dampers and their seismic performance during an earthquake. J Curr World Environ 10(1):1002–1015. https://doi.org/10.12944/CWE.10

2. ASTM C876-91 (1999) Standard test method for half-cell potentials of uncoated reinforcing steel in concrete. ASTM International, West Conshohocken

3. Banu D, Barros RCD, Taranu N (2012) Numerical modelling of two-way reinforced concrete slabs strengthened with carbon fiber reinforced polymers strips. In: International conference on experimental mechanics, Porto, Portugal, pp 1–7

4. Bozorgmehrnia S, Ranjbar MM, Madandoust R (2013) Seismic behavior assessment of concrete elevated water tanks. J Rehabil Civ Eng 1(2):69–79. https://doi.org/10.22075/jrce.2013.8

5. Fayyadh MM, Razak HA, Ismail Z (2011) Combined modal parameters-based index for damage identification in a beam like structure: theoretical development and verification. Arch Civ Mech Eng 11(3):587–609. https://doi.org/10.1016/S1644-9665(12)60103-4

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献