Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry

Author:

Alkhoury Ludvik,Choi Ji-won,Wang Chizhong,Rajasekar Arjun,Acharya Sayandeep,Mahoney Sean,Shender Barry S.,Hrebien Leonid,Kam MosheORCID

Abstract

AbstractCalculation of peripheral capillary oxygen saturation $${\text{(SpO}}_{{\text{2}}} {\text{)}}$$ (SpO 2 ) levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two $${\text{SpO}}_{{\text{2}}}$$ SpO 2 -level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. These techniques are: (1) “Red over Infrared,” calculating the ratios of AC and DC components of the red and infrared PPG signals,$$\frac{(AC/DC)_{red}}{(AC/DC)_{infrared}}$$ ( A C / D C ) red ( A C / D C ) infrared , followed by the use of a calibration curve to determine the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level Webster (in: Design of pulse oximeters, CRC Press, Boca Raton, 1997); and (2) a motion-resistant algorithm which uses the Discrete Saturation Transform (DST) (Goldman in J Clin Monit Comput 16:475–83, 2000). The DST algorithm isolates individual “saturation components” in the optical pathway, which allows separation of components corresponding to the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level from components corresponding to noise and interference, including motion artifacts. The comparison we provide here (employing the two techniques with and without pre-filtering) addresses two aspects: (1) accuracy of the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 calculations; and (2) computational complexity. We used both synthetic data and experimental data collected from human subjects. The human subjects were tested at rest and while exercising; while exercising, their measurements were subject to the impacts of motion. Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the “Red over Infrared” approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between $${\text{SpO}}_{{\text{2}}}$$ SpO 2 -level accuracy and computational complexity. A modest improvement in $${\text{SpO}}_{{\text{2}}}$$ SpO 2 estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level accuracy at −10 dB over unfiltered DST algorithm and the filtered “Red over Infrared” approach). However, this improvement comes at a significant computational cost.

Funder

Office of Naval Research

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine,Health Informatics

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3