Abstract
Abstract
Purpose
To evaluate quantitative and qualitative spermatic cord CT abnormalities and presence of unilateral or bilateral symptomatic scrotal pathology (SSP) at ultrasound.
Methods
This retrospective study included 122 male patients (mean age 47.8 years) undergoing scrotal ultrasound within 24 h of contrast-enhanced CT (n = 85), non-contrast CT (NECT, n = 32) or CT-Urogram (n = 5). CECT quantitative analysis assessed differential cord enhancement using maximum Hounsfield unit measurements. Three fellowship trained body radiologists independently assessed qualitative cord abnormalities for both CECT and NECT. Qualitative and quantitative findings were compared with the presence of SSP. Reader performance, interobserver agreement and reader confidence were assessed for NECT and CECT. Quantitative cutoff points were identified which maximized accuracy, specificity, negative predictive value, and other measures.
Results
SSP was present in 36/122 patients (29.5%). Positive cases were unilateral in 30 (83.3%) and bilateral in 6 (16.6%). At quantitative assessment, 25% differential cord enhancement had the highest diagnostic accuracy (88.9%), with 90.5% positive predictive value, 88.4% negative predictive value, 96.8% specificity, and 70.4% sensitivity. At qualitative evaluation, CECT reader performance was excellent (aggregate AUC = 0.86; P < .001); NECT was poorly discriminatory, although remained significant (aggregate AUC = 0.67; P = .002). Readers had significantly higher confidence levels with CECT (P < .001). Qualitative inter-observer agreement was high for both CECT and NECT (ICC = 0.981 and 0.963, respectively).
Conclusion
Simple quantitative assessment of differential cord enhancement is highly accurate and specific for SSP at CECT. Qualitative abnormalities at CECT and NECT are also both predictors of SSP, however, CECT significantly out-performs non-contrast exams.
Graphical abstract
Publisher
Springer Science and Business Media LLC