Can conventional DWI accurately assess the size of endometrial cancer?

Author:

Song YanfangORCID,Shang Hua,Ma Yumei,Li Xiaodong,Jiang Jingwen,Geng Zuojun,Shang Juan

Abstract

Abstract Purpose To compare T2-weighted image (T2WI) and conventional Diffusion-weighted image (cDWI) of magnetic resonance imaging (MRI) for sensitivity of qualitative diagnosis and accuracy of tumor size (TS) measurement in endometrial cancer (EC). Meanwhile, the effect of the lesion size itself and tumor grade on the ability of T2WI and cDWI of TS assessment was explored. Ultimately, the reason of deviation on size evaluation was studied. Materials and methods 34 patients with EC were enrolled. They were all treated with radical hysterectomy and performed MR examinations before operation. Firstly, the sensitivity of T2WI alone and T2WI–DWI in qualitative diagnosis of EC were compared according to pathology. Secondly, TS on T2WI and cDWI described with longitudinal (LD) and horizontal diameter (HD) were compared to macroscopic surgical specimen (MSS) quantitatively in the entire lesions and the subgroup lesions which grouped by postoperative tumor size itself and tumor grade. Thirdly, the discrepancy of mean ADC values (ADC mean) and range ADC values (ADC range) between different zones of EC were explored. Results For qualitative diagnosis, the sensitivity of T2WI–DWI (97%) was higher than T2WI alone (85%) (p = 0.046).For TS estimation, no significant difference (PLD = 0.579; PHD = 0.261) was observed between T2WI (LDT2WI = 3.90 cm; HDT2WI = 2.88 cm) and MSS (LD = 4.00 cm; HD = 3.06 cm), whereas TS of cDWI (LDDWI = 3.01 cm; HDDWI = 2.54 cm) were smaller than MSS (PLD = 0.002; PHD = 0.002) in all lesions. In subgroup of tumor with G1 (grade 1) and small lesion (defined as maximum diameter < 3 cm), both T2WI and cDWI were not significantly different from MSS; In subgroup of tumor with G2 + 3 (grade 2 and grade 3) and big lesion (maximum diameter ≥ 3 cm), T2WI matched well with MSS still, but DWI lost accuracy significantly. The result of ADC values between different zones of tumor showed ADC mean of EC rose from central zone to peripheral zone of tumor gradually and ADC range widened gradually. Conclusion cDWI can detect EC very sensitively. The TS on cDWI was smaller than the fact for the ECs with G2/3 and big size. The TS of T2WI was in accordance with the actual size for all ECs. The heterogeneity may be responsible for the inaccuracy of cDWI.

Publisher

Springer Science and Business Media LLC

Subject

Urology,Gastroenterology,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3