Purpose
Volumetric and health assessment of the liver is crucial to avoid poor post-operative outcomes following liver resection surgery. No current methods allow for concurrent and accurate measurement of both Couinaud segmental volumes for future liver remnant estimation and liver health using non-invasive imaging. In this study, we demonstrate the accuracy and precision of segmental volume measurements using new medical software, Hepatica™.
Methods
MRI scans from 48 volunteers from three previous studies were used in this analysis. Measurements obtained from Hepatica™ were compared with OsiriX. Time required per case with each software was also compared. The performance of technicians and experienced radiologists as well as the repeatability and reproducibility were compared using Bland–Altman plots and limits of agreement.
Results
High levels of agreement and lower inter-operator variability for liver volume measurements were shown between Hepatica™ and existing methods for liver volumetry (mean Dice score 0.947 ± 0.010). A high consistency between technicians and experienced radiologists using the device for volumetry was shown (± 3.5% of total liver volume) as well as low inter-observer and intra-observer variability. Tight limits of agreement were shown between repeated Couinaud segment volume (+ 3.4% of whole liver), segmental liver fibroinflammation and segmental liver fat measurements in the same participant on the same scanner and between different scanners. An underestimation of whole-liver volume was observed between three non-reference scanners.
Conclusion
Hepatica™ produces accurate and precise whole-liver and Couinaud segment volume and liver tissue characteristic measurements. Measurements are consistent between trained technicians and experienced radiologists.
Graphic abstract
Publisher
Springer Science and Business Media LLC
Subject
Urology,Gastroenterology,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Reference35 articles.
1. A. B. Ryerson et al., ‘Annual Report to the Nation on the Status of Cancer, 1975–2012, featuring the increasing incidence of liver cancer’, Cancer, vol. 122, no. 9, pp. 1312–1337, 01 2016, https://doi.org/10.1002/cncr.29936. 2. S. Manfredi, C. Lepage, C. Hatem, O. Coatmeur, J. Faivre, and A.-M. Bouvier, ‘Epidemiology and Management of Liver Metastases From Colorectal Cancer’, Annals of Surgery, vol. 244, no. 2, pp. 254–259, Aug. 2006, https://doi.org/10.1097/01.sla.0000217629.94941.cf. 3. R. Siegel, C. DeSantis, and A. Jemal, ‘Colorectal cancer statistics, 2014’, CA: A Cancer Journal for Clinicians, vol. 64, no. 2, pp. 104–117, 2014, https://doi.org/10.3322/caac.21220. 4. S. Mocellin, P. Pilati, M. Lise, and D. Nitti, ‘Meta-Analysis of Hepatic Arterial Infusion for Unresectable Liver Metastases From Colorectal Cancer: The End of an Era?’, Journal of Clinical Oncology, Sep. 2016, https://doi.org/10.1200/JCO.2007.12.1764. 5. J. K. Heimbach et al., ‘AASLD guidelines for the treatment of hepatocellular carcinoma’, Hepatology, vol. 67, no. 1, pp. 358–380, 2018, https://doi.org/10.1002/hep.29086.
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|