Semi-automated software improves interrater reliability and reduces processing time of magnetic resonance imaging-based exocrine pancreatic assessments in pediatric patients

Author:

Dudley Jonathan A.ORCID,Ata Nadeen Abu,Murdock Kyle E.,Vitale David S.,Abu-El-Haija Maisam,Trout Andrew T.

Abstract

Abstract Objectives Magnetic resonance (MR) imaging with secretin stimulation (MR-PFTs) is a non-invasive test for pancreatic exocrine function based on assessing the volume of secreted bowel fluid in vivo. Adoption of this methodology in clinical care and research is largely limited to qualitative assessment of secretion as current methods for secretory response quantification require manual thresholding and segmentation of MR images, which can be time-consuming and prone to interrater variability. We describe novel software (PFTquant) that preprocesses and thresholds MR images, performs heuristic detection of non-bowel fluid objects, and provides the user with intuitive semi-automated tools to segment and quantify bowel fluid in a fast and robust manner. We evaluate the performance of this software on a retrospective set of clinical MRIs. Methods Twenty MRIs performed in children (< 18 years) were processed independently by two observers using a manual technique and using PFTquant. Interrater agreement in measured secreted fluid volume was compared using intraclass correlation coefficients, Bland-Altman difference analysis, and Dice similarity coefficients. Results Interrater reliability of measured bowel fluid secretion using PFTquant was 0.90 (0.76–0.96 95% C.I.) with − 4.5 mL mean difference (-39.4–30.4 mL 95% limits of agreement) compared to 0.69 (0.36–0.86 95% C.I.) with − 0.9 mL mean difference (-77.3–75.5 mL 95% limits of agreement) for manual processing. Dice similarity coefficients were better using PFTquant (0.88 +/- 0.06) compared to manual processing (0.85 +/- 0.10) but not significantly (p = 0.11). Time to process was significantly (p < 0.001) faster using PFTquant (412 +/- 177 s) compared to manual processing (645 +/- 305 s). Conclusion Novel software provides fast, reliable quantification of secreted fluid volume in children undergoing MR-PFTs. Use of the novel software could facilitate wider adoption of quantitative MR-PFTs in clinical care and research.

Funder

National Institute of Diabetes and Digestive and Kidney Diseases

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3