Author:
Boni Federico,Désangles Victor,Jarrige Julien
Abstract
AbstractDirect thrust measurements have been performed on a low-power (30 W) ECR plasma thruster operated with xenon. The total thrust, the force exerted on the walls of the source (thermal thrust), and the force exerted on the permanent magnet (magnetic thrust) have been measured separately for various operating conditions (power and flowrate). The results are compared for two magnetic field topologies (with a different magnetic field gradient and divergence). The magnetic thrust dominates thermal thrust for most operating conditions, and its contribution to total thrust can be as high as 80%. A saturation of magnetic thrust with increasing power has been observed and is correlated with a decrease in thrust efficiency. A high degree of electron anisotropy can be inferred from the thrust measurements.
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献