Influence of Various Accessories Upstream Large Water Meters

Author:

Albaina IñigoORCID,Bidaguren Iñigo,Izquierdo Urko,Esteban G. A.

Abstract

AbstractThe focus of this study is on large flow meters, for which there is limited information due to their large size, making testing and research challenging. This research was conducted to quantify the effects of various accessories located upstream of these meters. Even a small percentage of variation in error can correspond to a significant volume of water. Accurate meters are crucial in many applications that involve large volumes of water as precise flow measurements are necessary for smooth and efficient processes while avoiding costly errors and downtime. Inaccurate large water meters can have far-reaching implications, such as overbilling or underbilling and production inefficiencies, which result in wasted resources and energy. Furthermore, inaccurate flow measurements can lead to environmental consequences as industries must comply with strict regulations regarding wastewater discharge limits. Uncertainty about the economic impact of an accessory installed upstream of a medium-sized water meter leads many water utilities to oversize the meter chambers to mitigate potential negative errors. In this study, six types of elements were tested upstream of ten brand-new water meters from six different manufacturers, constructed using four different metering technologies: single-jet, Woltmann, electromagnetic, and ultrasonic. Each meter unit was tested at five flow rates, ranging from the minimum to overload. The tests were conducted with accessories set in different orientations and distances upstream of the water meters under study. The research shows that the accessories used can cause significant deviations in measuring errors compared to the regular errors found under undisturbed working conditions.

Funder

Universidad del País Vasco

Publisher

Springer Science and Business Media LLC

Subject

Water Science and Technology,Civil and Structural Engineering

Reference45 articles.

1. Albaina I (2016) Análisis de la incidencia de las condiciones de instalación sobre el error de medición de los contadores de agua no-domésticos y su repercusión económica. PhD Thesis, Universidad del País Vasco/Euskal Herriko Unibertsitatea

2. Albaina I, Arregui FJ, Bidaguren-Alday C, Bidaguren I (2020) Influence of butterfly and gate valves upstream large water meters. Water (Switzerland) 12. https://doi.org/10.3390/W12092563

3. Albaina I, Esteban GA, Bidaguren I, Izquierdo U (2023) New switching gate diverter valve for large flow measurement systems. Flow Meas Instrum 93:102425. https://doi.org/10.1016/j.flowmeasinst.2023.102425

4. American Water Works Association (AWWA) (2012) Water Meters-Selection, Installation, Testing, and Maintenance. AWWA Manual M6

5. American Water Works Association (AWWA) (2011) Flowmeters in Water Supply, 2nd Ed. (M33)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3