Abstract
AbstractThe focus of this study is on large flow meters, for which there is limited information due to their large size, making testing and research challenging. This research was conducted to quantify the effects of various accessories located upstream of these meters. Even a small percentage of variation in error can correspond to a significant volume of water. Accurate meters are crucial in many applications that involve large volumes of water as precise flow measurements are necessary for smooth and efficient processes while avoiding costly errors and downtime. Inaccurate large water meters can have far-reaching implications, such as overbilling or underbilling and production inefficiencies, which result in wasted resources and energy. Furthermore, inaccurate flow measurements can lead to environmental consequences as industries must comply with strict regulations regarding wastewater discharge limits. Uncertainty about the economic impact of an accessory installed upstream of a medium-sized water meter leads many water utilities to oversize the meter chambers to mitigate potential negative errors. In this study, six types of elements were tested upstream of ten brand-new water meters from six different manufacturers, constructed using four different metering technologies: single-jet, Woltmann, electromagnetic, and ultrasonic. Each meter unit was tested at five flow rates, ranging from the minimum to overload. The tests were conducted with accessories set in different orientations and distances upstream of the water meters under study. The research shows that the accessories used can cause significant deviations in measuring errors compared to the regular errors found under undisturbed working conditions.
Funder
Universidad del País Vasco
Publisher
Springer Science and Business Media LLC
Subject
Water Science and Technology,Civil and Structural Engineering
Reference45 articles.
1. Albaina I (2016) Análisis de la incidencia de las condiciones de instalación sobre el error de medición de los contadores de agua no-domésticos y su repercusión económica. PhD Thesis, Universidad del País Vasco/Euskal Herriko Unibertsitatea
2. Albaina I, Arregui FJ, Bidaguren-Alday C, Bidaguren I (2020) Influence of butterfly and gate valves upstream large water meters. Water (Switzerland) 12. https://doi.org/10.3390/W12092563
3. Albaina I, Esteban GA, Bidaguren I, Izquierdo U (2023) New switching gate diverter valve for large flow measurement systems. Flow Meas Instrum 93:102425. https://doi.org/10.1016/j.flowmeasinst.2023.102425
4. American Water Works Association (AWWA) (2012) Water Meters-Selection, Installation, Testing, and Maintenance. AWWA Manual M6
5. American Water Works Association (AWWA) (2011) Flowmeters in Water Supply, 2nd Ed. (M33)