Author:
Juelke Eirik,Butzer Tobias,Yacoub Abraam,Wimmer Wilhelm,Caversaccio Marco,Anschuetz Lukas
Abstract
Abstract
Purpose
High-riding jugular bulbs (JBs) among other anatomical variations can limit surgical access during lateral skull base surgery or middle ear surgery and must be carefully assessed preoperatively. We reconstruct 3D surface models to evaluate recent JB classification systems and assess the variability in the JB and surrounding structures.
Methods
3D surface models were reconstructed from 46 temporal bones from computed tomography scans. Two independent raters visually assessed the height of the JB in the 3D models. Distances between the round window and the JB dome were measured to evaluate the spacing of this area. Additional distances between landmarks on surrounding structures were measured and statistically analyzed to describe the anatomical variability between and within subjects.
Results
The visual classification revealed that 30% of the specimens had no JB, 63% a low JB, and 7% a high-riding JB. The measured mean distance from the round window to the jugular bulb ranges between 3.22 ± 0.97 mm and 10.34 ± 1.41 mm. The distance measurement (error rate 5%) was more accurate than the visual classification (error rate 15%). The variability of the JB was higher than for the surrounding structures. No systematic laterality was found for any structure.
Conclusion
Qualitative analysis in 3D models can contribute to a better spatial orientation in the lateral skull base and, thereby, have important implications during planning of middle ear and lateral skull base surgery.
Funder
Gottfried und Julia Bangerter-Rhyner-Stiftung
UniBern Forschungsstiftung
KARL STORZ
Carigest SA
Stiftung für technische und naturwissenschaftliche Forschung
University of Bern
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Pathology and Forensic Medicine,Surgery,Anatomy
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献