Author:
Concannon J.,Moerman KM,Hynes N.,Sultan S.,McGarry JP
Abstract
AbstractThe effect of repair techniques on the biomechanics of the aorta is poorly understood, resulting in significant levels of postoperative complications for patients worldwide. This study presents a computational analysis of the influence of Nitinol-based devices on the biomechanical performance of a healthy patient-specific human aorta. Simulations reveal that Nitinol stent-grafts stretch the artery wall so that collagen is stretched to a straightened high-stiffness configuration. The high-compliance regime (HCR) associated with low diastolic lumen pressure is eliminated, and the artery operates in a low-compliance regime (LCR) throughout the entire cardiac cycle. The slope of the lumen pressure–area curve for the LCR post-implantation is almost identical to that of the native vessel during systole. This negligible change from the native LCR slope occurs because the stent-graft increases its diameter from the crimped configuration during deployment so that it reaches a low-stiffness unloading plateau. The effective radial stiffness of the implant along this unloading plateau is negligible compared to the stiffness of the artery wall. Provided the Nitinol device unloads sufficiently during deployment to the unloading plateau, the degree of oversizing has a negligible effect on the pressure–area response of the vessel, as each device exerts approximately the same radial force, the slope of which is negligible compared to the LCR slope of the native artery. We show that 10% oversizing based on the observed diastolic diameter in the mid descending thoracic aorta results in a complete loss of contact between the device and the wall during systole, which could lead to an endoleak and stent migration. 20% oversizing reaches the Dacron enforced area limit (DEAL) during the pulse pressure and results in an effective zero-compliance in the later portion of systole.
Funder
Irish Research Council
National University Ireland, Galway
Publisher
Springer Science and Business Media LLC
Subject
Mechanical Engineering,Modelling and Simulation,Biotechnology
Reference81 articles.
1. Aaron BB, Gosline JM (1981) Elastin as a random-network elastomer: a mechanical and optical analysis of single elastin fibers. Biopolymers 20(6):1247–1260. https://doi.org/10.1002/BIP.1981.360200611
2. Abbaszadeh, Shahin, Mahdieh Eslami, and Marzieh Nikparvar. 2019. “Aortic Dissection in an 11-Year-Old Boy: Case Report Abbaszadeh et Al Case Report Aortic Dissection in an 11-Year-Old Boy: Case Report Aortic Dissection in an 11-Year-Old Boy: Case Report.” Iranian Heart Journal. Vol. 20
3. Abbott WM, Megerman J, Hasson JE, Italien GL, Warnock DF (1987) Effect of compliance mismatch on vascular graft patency. J Vasc Surg 5(2):376–82
4. Atti V, Nalluri N, Kumar V, Tabet R, Yandrapalli S, Edla S, Tripathi A et al (2018) Frequency of 30-Day readmission and its causes after endovascular aneurysm intervention of abdominal aortic aneurysm (from the nationwide readmission database). Am J Cardiol. https://doi.org/10.1016/J.AMJCARD.2018.12.006
5. Auricchio F, Taylor RL (1997) Shape-Memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior. Comput Methods Appl Mech Eng 143(1–2):175–194. https://doi.org/10.1016/S0045-7825(96)01147-4
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献