Abstract
Abstract
Objective
This study evaluates the early results of our initial experience with aortic annuloplasty using a complete external Dacron band in the setting of type Ic or type II aortic regurgitation (AR).
Methods
From May 2017 to August 2019, 16 patients (88% bicuspid aortic valves, no patients with connective tissue disorders) underwent aortic annuloplasty with an external complete Dacron band. Clinical and echocardiographic follow-up was 100% complete. Clinical and echocardiographic follow-up averaged 24.4 ± 9.3 and 15.1 ± 8.3 months, respectively.
Results
Mean cardiopulmonary and cross-clamp times were 105 ± 15 (72–127) and 86 ± 15 (51–113) min, respectively. Early and late mortality was 0%, with no incidents of endocarditis or cerebrovascular events during the follow-up. Two patients were re-operated during the follow-up, one due recurrent aortic regurgitation (12 months after the first operation) yielding a freedom from reoperation due to AR at 1 year and 3 years of 100% ± 0% and 93.3% ± 5.7%, respectively. Based on the latest echocardiogram, five patients had either none or trivial AR, six had mild AR, and three had mild-to-moderate AR.
Conclusions
The early clinical and echocardiographic results after using a complete external Dacron band are promising; however, more data and longer follow-up are needed to determine its role in annular management during aortic valve repair.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献