The ventilation parameters during the Nuss procedure for repair of pectus excavatum

Author:

Myhal I.I., ,Fesenko U.A.,Dvorakevich A.O.,Albokrinov A.A., , ,

Abstract

The ventilation parameters during the Nuss procedure for repair of pectus excavatum depend on surgical procedures and airway protection technique. The aim of the study: analyzing the ventilation parameters during the Nuss procedure for repair of pectus excavatum according to the airway protection technique. Material and Methods. The observational prospective study included 60 adolescents (boys/girls=47/13) who had undergone the Nuss procedure for repair of pectus excavatum under a combination of general anesthesia with different types of regional blocks. The patients were randomized into two groups (n=20 in each) according to the airway protection technique: Group S (n=32) where the patients were intubated with a standard single-lumen tube, and capnothorax with 4-6 mmHg intrapleural pressure was applied; Group D (n=28) where the patients were intubated with a double-lumen tube, and open pneumothorax was applied without additional pressure in the thoracic cavity. All patients were ventilated using PCV with changing of the parameters in relevance with EtCO2. The following parameters were analyzed: peripheral blood saturation (SpO2), inspiratory fractional oxygen concentration (FiO2), end-tidal carbon dioxide partial pressure (EtCO2), tidal volume (Tv), peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), the number of repeated intubation attempts, and the quality of operation field visualization checked by surgeon with a 5-point scale. Results and Discussion. During capno/pneumothorax and bar rotation, in both groups SpO2 decreased up to 95%, which required increasing FiO2 up to 70% in Group D, and up to 63% in Group S (р=0.04). Applying capno/pneumothorax lead to reduced Tv, which was 52 ml less in Group D than in Group S (р=0.0001). The levels of EtCO2, PIP, and PEEP were comparable in both groups at all stages of the surgery. The number of repeated intubation attempts was- 1 case (3,1%) in group S, and 2 cases (7,1%) in group D: c2 = 0,51; p=0.48, the adjusted c22 = 3.84 for p <0.05. The quality of operation field visualization evaluated by the surgeons with the 5-point scale was better in Group D (4.5 points), than in Group S - 3 points (р<0.000001) at all stages. Conclusions. The one-lung ventilation using double-lumen left-side tube provides better operating field visualization than ventilation throw single-lumen tube with capnothorax. Both techniques supply adequate ventilation and oxygenation parameters. Key words: tracheal intubation, ventilation, pectus excavatum, Nuss procedure

Publisher

Danylo Halytskyi Lviv National Medical University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3