DIAGNOSIS OF LEFT VENTRICULAR DIASTOLIC DYSFUNCTION ON RESTING ECG – A PROSPECTIVE STUDY

Author:

Sivaram Kalavakolanu Sharada1,Priya Mohana2

Affiliation:

1. Associate Professor,Department of Cardiology.

2. Cardiac Technician.

Abstract

Background: Heart failure due to preserved as well as reduced ejection fraction is a major healthcare challenge; echocardiography, including tissue Doppler Imaging (TDI) serves as the cornerstone of its diagnosis. ECG is a widely available,relatively inexpensive tool for predicting left ventricular diastolic dysfunction (LVDD). Objectives:We aimed to study different parameters in resting 12-lead ECG to evaluate whether they can predict LVDD diagnosed on detailed echocardiography including TDI. Methods: This was a cross-sectional study of 39 patients undergoing echocardiographic study in cardiology department of our institute.They were classified into two groups based on LVDD (Group 1 Normal, Group 2 LVDD) and their resting 12-lead ECG was analyzed for following parameters: QT interval, corrected QT interval, P wave duration (PW-D) and height (PW-H) in Lead 2, P terminal wave duration (P term-D) and height ( P term-H) in lead V1, P wave terminal force in lead V1.Correlation of these parameters with LVDD was investigated. Results: Study included 39 patients,females 16,males 23,with age range 20-87 (mean 48) years.Group 1 comprised of 14 normal echo patients and 25 patients with LVDD were in Group 2. The Mean QTc was 419ms (SD 21) and 440ms (SD 30) in Group 1 and Group 2 respectively, which was statistically significant (p =0.03). The P terminal wave duration V1 difference was statistically significant (p 0.03) with a mean of 39±17 ms vs 52±19 ms in Grp 1 and Grp 2 respectively. P terminal wave height V1 was 0.79±0.26 mm in Grp 1 and 1.1±0.41 mm in Grp 2, which was statistically significant (p= 0.01). Morris Index was statistically highly significant between the two groups (0.03±0.02 mm.s Grp1 and 0.07±0.04 mm.s in Grp2,p 0.009).P wave height lead 2 was 1.1±0.4 mm and 1.7±0.6 mm in Grp 1 and Grp 2 respectively (p= 0.002). P wave duration in Lead 2 did not find significance statistically (p 0.08) with mean 90±19 ms versus 103±26ms in Group 1 and 2 respectively. Conclusion: QTc, P terminal wave duration and amplitude in V1, Morris Index, and P wave amplitude in lead 2 are significantly higher in patients with echocardiographic diagnosis of LVDD.

Publisher

World Wide Journals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3