SECONDARY INTERNAL OSTEOSYNTHESIS WITH LOCKING PLATES FOR RECENT OR OLD OPEN FRACTURE OF THE TIBIA, OVERLAPPING PROVISIONAL EXTERNAL FIXATOR PIN SITES: IS THE INFECTION RISK INCREASED?

Author:

Kumar Garg Uttam1,K Shukla S.1,K Pathak S.1,A Usmani I.1

Affiliation:

1. Department of Orthopaedic Surgery, Career Institute of Medical Sciences and Hospital, Lucknow, Uttar Pradesh, India.

Abstract

Twenty-two patients had a severe open fracture of the tibia that was initially treated by external fixation and subsequently by locking plate. The external fixation had been maintained for an average of fifty-nine days (range, 15 to 240 days). The mean interval between removal of the external fixator and plating was twenty-six days (range, 10 to 44 days). five out of twelve patients who had an infection at one or more of the pin sites, developed one superficial and four deep infection. In comparison, only one of the ten patients who had not had a pin-site infection had a superficial infection. An analysis of other variables, including the duration of external fixation, wound coverage, other injuries, and the type of fracture, showed that none was a predictor of infection either at the pin sites or around the plate. We concluded that a pin-site infection that develops during external fixation is a contraindication to the subsequent plating in patients who have a fracture of the tibia.

Publisher

World Wide Journals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3