COMPARISON OF LOW KVP SIZE BASED LOW DOSE CT PROTOCOL AND LOW KVP AUTOMATED EXPOSURE CONTROLLED BASED LOW DOSE CT PROTOCOL, FOR EVALUATION OF CONGENITAL HEART DISEASE IN PAEDIATRIC POPULATION IN A TERTIARY CARE TEACHING HOSPITAL OF WESTERN RAJASTHAN.

Author:

Vishnoi Sunil1,Chaturvedy Kirti2,Gehlot Ramanand3,Mishra Divyangi4,Nandvanshi Girja1,H. P Anish1,Kaushik Abhishek1,kammar Asaf Ali1

Affiliation:

1. 3rd Year PG Student, Department of Radio-diagnosis, Dr. S. N. Medical College, Jodhpur, Rajasthan, India

2. Professor and Head, Department of Radio-diagnosis, Dr. S. N. Medical College, Jodhpur, Rajasthan, India

3. Senior Professor, Department of Radio-diagnosis, Dr. S. N. Medical College, Jodhpur, Rajasthan, India

4. Assistant Professor, Department of Radio-diagnosis, Dr. S. N. Medical College, Jodhpur, Rajasthan, India

Abstract

ntroduction: Evaluation for CHD lead to inadvertent radiation exposure to children. With objective of minimising radiation exposure, we developed a size based (SB) novel low kVp low dose CT protocol for pediatrics population. All CT chest examinationsMaterial and methods: performed on PHILIPS Ingenuity core 64-slice multi detector CT machine. A total of sixty children with suspected/diagnosed CHD were randomized to either novel SB protocol or machine's default AEC based low dose pediatric chest CT protocol . Our protocol consisted of keeping tube voltage 80 kVp in all patients and tube current (mA) being modulated according to size of subjects (chest circumference). All CT dose parameters (ED, CTDI vol, DLP and mA) were recorded for comparison. Image quality of the two methods compared by two radiologists blinded to the method. After analysing and comparing with other studies for all the CT dose variables we concluded that all CT radiation exposureResults: values as measured by ED, CTDI vol, SSDE, DLP were lower in SB protocol as comparison to default AEC based protocol in those corresponding to <12 months age group. In 1-5 year- ED, SSDE, CTDI vol and DLP was equivalent in both size based and AEC based low dose protocols. In 6-18 year ED, SSDE, CTDI vol and DLP was slightly higher in size based low dose protocol. In younger age group ( <12 months of age) SBConclusion: protocol should be preferred as compared to default machine protocol. In children with >1 years of age , low dose AEC protocol is better from perspective of radiation exposure.

Publisher

World Wide Journals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3