DIAGNOSTIC ACCURACY OF CONTRAST ENHANCED ULTRASONOGRAPHY IN FOCAL LIVER LESIONS DETECTED BY CONTRAST ENHANCED COMPUTED TOMOGRAPHY

Author:

Gnanasigamani Sathyan1,Chellathurai Amarnath2,Priya Priya3,Sivakumar Sivakumar3,Karthikrajan Karthikrajan4

Affiliation:

1. Professor,Department of Radio diagnosis,Govt.stanley medical college,Chennai-600001.

2. Professor and Head of the department, Govt.stanley medical college,Chennai-600001.

3. Assistant professor, Department of Radio diagnosis,Govt.stanley medical college, Chennai-600001.

4. Junior Resident, Department of Radio diagnosis,Govt.stanley medical college,Chennai600001.

Abstract

Context: Contrast enhanced Ultrasonography(CEUS) has improved the detection and characterization of focal liver lesions, offering comparable results to those with contrast CT when ultra-sound exploration is technically satisfactory.The vascular property of the lesion in arterial, portal and delayed phases by enhancement and washout is used in this technique. Aim: The aim of the study is to interpret the use of contrast-enhanced ultra-sound (CEUS) in characterising the focal liver lesions and compare the diagnostic accuracy of the contrast-enhanced ultra-sound with contrast enhanced CT Materials and Methods: This is a cross sectional analytical study in patients with focal liver lesions detected by USG/CECT coming to Department of Radio diagnosis in Government Stanley Hospital.The duration of the study is two and a half years from January 2017 to July 2019.Sample Size was total of 51 patients detected by CECT /USG as focal liver lesions registered in Govt. Stanley Medical College Hospital between January 2017 to July 2019. Results: Diagnostic accuracy for CEUS is 76.46 % and CECT is 83.9%. Sensitivity, specificity , PPV ,NPV and Diagnostic accuracy of the CEUS is almost near equal or comparable with that of CECT. Conclusion: CEUS has ability to detect and characterise of focal liver lesions with no risk of radiation exposure and aids in real time imaging assessment.The study parameters like sensitivity, specificity and diagnostic accuracy of the CEUS are comparable with that of CECT.CEUS can be used to characterise the focal liver lesions in patients where CECT is contraindicated.

Publisher

World Wide Journals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3