Underestimation of Glucose Turnover Measured With [6-3H]- and [6,6-2 H2]- but not [6-14C]glucose During Hyperinsulinemia in Humans

Author:

McMahon M Molly1,Schwenk W Frederick1,Haymond Morey W1,Rizza Robert A1

Affiliation:

1. Endocrine Research Unit, Departments of Medicine and Pediatrics, Mayo Clinic, Rochester, Minnesota

Abstract

Recent studies indicate that hydrogen-labeled glucose tracers underestimate glucose turnover in humans under conditions of high flux. The cause of this underestimation is unknown. To determine whether the error is time-, pool-, model-, or insulin-dependent, glucose turnover was measured simultaneously with [6-3H]-, [6,6-2H2]-, and [6-14C]glucose during a 7-h infusion of either insulin (1 mU · kg−1 · min−1) or saline. During the insulin infusion, steady-state glucose turnover measured with both [6-3H]glucose (8.0 ± 0.5 mg · kg−1 · min−1) and [6,6-2H2]glucose (7.6 ± 0.5 mg kg−1 min−1) was lower (P < .01) than either the glucose infusion rate required to maintain euglycemia (9.8 ± 0.6 mg · kg−1 · min−1) or glucose turnover determined with [6-14 C]glucose and corrected for Cori cycle activity (9.8 ± 0.7 mg · kg−1 · min1). Consequently “negative” glucose production rates (P <.01) were obtained with either [6-3 H]- or [6,6-2 H2]-but not [6-14 C]glucose. The difference between turnover estimated with [6-3 H]glucose and actual glucose disposal (or 14C glucose flux) did not decrease with time and was not dependent on duration of isotope infusion. During saline infusion, estimates of glucose turnover were similar regardless of the glucose tracer used. High-performance liquid chromatography of the radioactive glucose tracer and plasma revealed the presence of a tritiated nonglucose contaminant. Although the contaminant represented only 1.5% of the radioactivity in the [6-3H]glucose infusate, its clearance was 10-fold less (P <.001) than that of [6-3H]glucose. This resulted in accumulation in plasma, with the contaminant accounting for 16.6 ± 2.09 and 10.8 ± 0.9% of what customarily is assumed to be plasma glucose radioactivity during the insulin or saline infusion, respectively (P < .01). When corrected for the presence of the contaminant, glucose turnover determined with [6-3H]glucose during insulin infusion (9.5 ± 0.6 mg · kg−1 · min−1) no longer differed from either the glucose infusion rate or that determined with [6-14C]glucose. Therefore, the underestimation of glucose turnover during insulin infusion and negative glucose production rates observed with traditional methods to analyze plasma radioactivity and commercially available tracers is the result of an artifactual increase in [6-3H]glucose specific activity. The etiology of the underestimation of glucose turnover with [6,6-2H2]glucose remains to be determined.

Publisher

American Diabetes Association

Subject

Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 46 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3