Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial Pancreas

Author:

Weinzimer Stuart A.1,Steil Garry M.2,Swan Karena L.1,Dziura Jim3,Kurtz Natalie2,Tamborlane William V.13

Affiliation:

1. Department of Pediatrics, Yale University School of Medicine, New Haven, Connecticut

2. Medtronic MiniMed, Northridge, California

3. Yale Center for Clinical Investigation, Yale University School of Medicine, New Haven, Connecticut

Abstract

OBJECTIVE—The most promising β-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characteristics of the β-cell. However, delays in insulin absorption associated with the subcutaneous route of delivery inevitably lead to large postprandial glucose excursions. RESEARCH DESIGN AND METHODS—We studied the feasibility of the Medtronic ePID system in youth with type 1 diabetes and hypothesized that small manual premeal “priming” boluses would reduce postprandial excursions during closed-loop control. Seventeen adolescents (aged 15.9 ± 1.6 years; A1C 7.1 ± 0.8%) underwent 34 h of closed-loop control; 8 with full closed-loop (FCL) control and 9 with hybrid closed-loop (HCL) control (premeal priming bolus). RESULTS—Mean glucose levels were 135 ± 45 mg/dl in the HCL group versus 141 ± 55 mg/dl in the FCL group (P = 0.09); daytime glucose levels averaged 149 ± 47 mg/dl in the HCL group versus 159 ± 59 mg/dl in the FCL group (P = 0.03). Peak postprandial glucose levels averaged 194 ± 47 mg/dl in the HCL group versus 226 ± 51 mg/dl in the FCL group (P = 0.04). Nighttime control was similar in both groups (111 ± 27 vs. 112 ± 28 mg/dl). CONCLUSIONS—Closed-loop glucose control using an external sensor and insulin pump provides a means to achieve near-normal glucose concentrations in youth with type 1 diabetes during the overnight period. The addition of small manual priming bolus doses of insulin, given 15 min before meals, improves postprandial glycemic excursions.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3