Reference Values for Continuous Glucose Monitoring in Chinese Subjects

Author:

Zhou Jian1,Li Hong2,Ran Xingwu3,Yang Wenying4,Li Qiang5,Peng Yongde6,Li Yanbing7,Gao Xin8,Luan Xiaojun9,Wang Weiqing10,Jia Weiping1

Affiliation:

1. Department of Endocrinology and Metabolism, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Diabetes Institute, Shanghai Clinical Center for Diabetes, Shanghai, China;

2. Department of Endocrinology and Metabolism, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China;

3. Department of Endocrinology and Metabolism, West China Hospital, Sichuan University, Chengdu, China;

4. Department of Endocrinology and Metabolism, China-Japan Friendship Hospital, Beijing, China;

5. Department of Endocrinology and Metabolism, The Second Affiliated Hospital of Harbin Medical University, Harbin, China;

6. Department of Endocrinology and Metabolism, Shanghai Jiao Tong University Affiliated First People's Hospital, Shanghai, China;

7. Department of Endocrinology and Metabolism, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China;

8. Department of Endocrinology and Metabolism, Fudan University Affiliated Zhongshan Hospital, Shanghai, China;

9. Department of Endocrinology and Metabolism, The First People's Hospital of Foshan, Foshan, China;

10. Shanghai Clinical Center for Endocrine and Metabolic Diseases, Shanghai Institute of Endocrinology and Metabolism, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Abstract

OBJECTIVE The widespread clinical application of continuous glucose monitoring (CGM) is limited by the lack of generally accepted reference values. This multicenter study aims to establish preliminary normal reference values for CGM parameters in a sample of healthy Chinese subjects. RESEARCH DESIGN AND METHODS A total of 434 healthy individuals with normal glucose regulation completed a 3-day period of glucose monitoring using a CGM system. The 24-h mean blood glucose (24-h MBG) and the percentage of time that subjects' blood glucose levels were ≥140 mg/dl (PT140) and ≤70 mg/dl (PT70) within 24 h were analyzed. RESULTS There was excellent compliance of finger stick blood glucose values with CGM measurements for subjects. Among the 434 subjects, the daily blood glucose varied from 76.9 ± 11.3 to 144.2 ± 23.2 mg/dl. The 24-h MBG, PT140, and PT70 were 104 ± 10 mg/dl, 4.1 ± 5.8%, and 2.4 ± 5.3%, respectively. As for these parameters, no significant differences were found between men and women. The 95th percentile values were adopted as the upper limits of CGM parameters, which revealed 119 mg/dl (6.6 mmol/l) for 24-h MBG, 17.1% for PT140, and 11.7% for PT70. CONCLUSIONS We recommend a 24-h MBG value <119 mg/dl, PT140 <17% (4 h), and PT70 <12% (3 h) as normal ranges for the Chinese population.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3