Day-and-Night Closed-Loop Insulin Delivery in a Broad Population of Pregnant Women With Type 1 Diabetes: A Randomized Controlled Crossover Trial

Author:

Stewart Zoe A.12,Wilinska Malgorzata E.1,Hartnell Sara2,O’Neil Leanne K.3,Rayman Gerry4ORCID,Scott Eleanor M.5,Barnard Katharine6,Farrington Conor7,Hovorka Roman1,Murphy Helen R.1238ORCID

Affiliation:

1. Wellcome Trust–Medical Research Council Institute of Metabolic Science, University of Cambridge, Cambridge, U.K.

2. Wolfson Diabetes and Endocrine Clinic, Cambridge University Hospitals NHS Foundation Trust, Cambridge, U.K.

3. Elsie-Bertram Diabetes Centre, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, U.K.

4. Ipswich Diabetes Centre, Ipswich Hospital NHS Trust, Ipswich, U.K.

5. Division of Epidemiology and Biostatistics, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, U.K.

6. Faculty of Health and Social Science, Bournemouth University, Bournemouth, U.K.

7. Cambridge Centre for Health Services Research, University of Cambridge, Cambridge, U.K.

8. Norwich Medical School, University of East Anglia, Norwich, U.K.

Abstract

OBJECTIVE Despite advances in technology, optimal glucose control remains elusive and neonatal complications remain ubiquitous in type 1 diabetes (T1D) pregnancy. Our aim was to examine the safety, efficacy, and longer-term feasibility of day-and-night closed-loop insulin delivery. RESEARCH DESIGN AND METHODS We recruited 16 pregnant women (mean [SD]: age 32.8 [5.0] years, T1D duration 19.4 [10.2] years, HbA1c 8.0% [1.1], and BMI 26.6 [4.4] kg/m2) to an open-label, randomized, crossover trial. Participants completed 28 days of closed-loop and sensor-augmented pump (SAP) insulin delivery separated by a washout period. Afterward, participants could continue to use the closed-loop system up to 6 weeks postpartum. The primary end point was the proportion of time with glucose levels within the target range (63–140 mg/dL). RESULTS The proportion of time with glucose levels within target was comparable during closed-loop and SAP insulin delivery (62.3 vs. 60.1% [95% CI −4.1 to 8.3]; P = 0.47). Mean glucose and time spent hyperglycemic >140 mg/dL also did not differ (131.4 vs. 131.4 mg/dL [P = 0.85] and 36.6 vs. 36.1% [P = 0.86], respectively). During closed-loop, fewer hypoglycemic episodes occurred (median 8 [range 1–17] vs. 12.5 [1–53] over 28 days; P = 0.04) and less time at <63 mg/dL (1.6 vs. 2.7%; P = 0.02). Hypoglycemia <50 mg/dL (0.24 vs. 0.47%; P = 0.03) and low blood glucose index (1.0 vs. 1.4; P = 0.01) were lower. Less nocturnal hypoglycemia (2300–0700 h) during closed-loop therapy (1.1 vs. 2.7%; P = 0.008) and a trend toward higher overnight time in target (67.7 vs. 60.6%; P = 0.06) were found. CONCLUSIONS Closed-loop insulin delivery was associated with comparable glucose control and significantly less hypoglycemia than SAP therapy. Larger, longer-duration multicenter trials are now indicated to determine clinical efficacy of closed-loop insulin delivery in T1D pregnancy and the impact on neonatal outcomes.

Funder

Gates Cambridge Trust

National Institute for Health Research

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3