Affiliation:
1. Department of Medicine, University of Goteborg and Department of Clinical Chemistry, University of Linkoping Sweden
Abstract
To evaluate the interstitial insulin and inulin concentrations, 20-min microdialysis samples from the abdominal subcutaneous tissue were obtained by using two 45-mm polypropylene dialyzing tubes (o.d. ∼ 0.5 mm, pore size 0.2 micron) during a euglycemic hyperinsulinemic (120 mU · m−2 · min−1) clamp (n = 9) or during a constant inulin infusion (n = 5). After in situ calibration of the microdialysis catheters during steady-state conditions, interstitial and plasma insulin concentrations were estimated to 654 ± 102 and 1176 ± 66 pM, respectively, i.e., a 44% difference (P < 0.001). A doubling of the insulin infusion rate (240 mU · m−2 · m−1), leading to supraphysiological plasma insulin levels, raised the interstitial insulin concentrations markedly slower (∼20 min) than in plasma. Moreover, at steady state the concentration difference in the two compartments prevailed even during the high insulin infusion rate (55% difference, P < 0.01). In contrast, the interstitial inulin levels were similar to the plasma concentrations in subjects given a constant inulin infusion. Thus, the data suggest the presence of an endothelial barrier for insulin in the subcutaneous tissue. This barrier, in combination with tissue clearance of insulin, leads to lower insulin levels and altered kinetics with a slower rise in the interstitial fluid compared with plasma.
Publisher
American Diabetes Association
Subject
Endocrinology, Diabetes and Metabolism,Internal Medicine
Cited by
67 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献