Detection of Abnormal Glucose Tolerance in Africans Is Improved by Combining A1C With Fasting Glucose: The Africans in America Study

Author:

Sumner Anne E.1,Thoreson Caroline K.1,O'Connor Michelle Y.1,Ricks Madia1,Chung Stephanie T.1,Tulloch-Reid Marshall K.2,Lozier Jay N.3,Sacks David B.3

Affiliation:

1. Diabetes, Endocrinology, and Obesity Branch, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD

2. Tropical Medicine Research Institute, University of the West Indies, Kingston, Jamaica

3. Department of Laboratory Medicine, Clinical Center, National Institutes of Health, Bethesda, MD

Abstract

OBJECTIVE Abnormal glucose tolerance is rising in sub-Saharan Africa. Hemoglobin A1c by itself and in combination with fasting plasma glucose (FPG) is used to diagnose abnormal glucose tolerance. The diagnostic ability of A1C in Africans with heterozygous variant hemoglobin, such as sickle cell trait or hemoglobin C trait, has not been rigorously evaluated. In U.S.-based Africans, we determined by hemoglobin status the sensitivities of 1) FPG ≥5.6 mmol/L, 2) A1C ≥ 5.7% (39 mmol/mol), and 3) FPG combined with A1C (FPG ≥5.6 mmol/L and/or A1C ≥5.7% [39 mmol/mol]) for the detection of abnormal glucose tolerance. RESEARCH DESIGN AND METHODS An oral glucose tolerance test (OGTT) was performed in 216 African immigrants (68% male, age 37 ± 10 years [mean ± SD], range 20–64 years). Abnormal glucose tolerance was defined as 2-h glucose ≥7.8 mmol/L. RESULTS Variant hemoglobin was identified in 21% (46 of 216). Abnormal glucose tolerance occurred in 33% (72 of 216). When determining abnormal glucose tolerance from the OGTT (2-h glucose ≥7.8 mmol/L), sensitivities of FPG for the total, normal, and variant hemoglobin groups were 32%, 32%, and 33%, respectively. Sensitivities for A1C were 53%, 54%, and 47%. For FPG and A1C combined, sensitivities were 64%, 63%, and 67%. Sensitivities for FPG and A1C and the combination did not vary by hemoglobin status (all P > 0.6). For the entire cohort, sensitivity was higher for A1C than FPG and for both tests combined than for either test alone (all P values ≤ 0.01). CONCLUSIONS No significant difference in sensitivity of A1C by variant hemoglobin status was detected. For the diagnosis of abnormal glucose tolerance in Africans, the sensitivity of A1C combined with FPG is significantly superior to either test alone.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3