Use of insulin lispro in continuous subcutaneous insulin infusion treatment. Results of a multicenter trial. German Humalog-CSII Study Group.

Author:

Renner R1,Pfützner A1,Trautmann M1,Harzer O1,Sauter K1,Landgraf R1

Affiliation:

1. 3rd Medical Department, Hospital München-Bogenhausen, Germany.

Abstract

OBJECTIVE: Insulin lispro is an analog of human insulin with a faster onset and a shorter duration of action than regular human insulin. Efficacy and tolerability of insulin lispro in continuous subcutaneous insulin infusion (CSII) treatment were assessed in an open randomized crossover trial comparing insulin lispro and regular human insulin, both applied with insulin pumps. RESEARCH DESIGN AND METHODS: A total of 113 type 1 patients (60 male, 53 female, age [mean +/- SD] 37 +/- 12 years, duration of diabetes 19 +/- 9 years) participated in this open, randomized crossover study. Both insulins were applied for 4 months each with the appropriate intervals between the prandial insulin bolus and the meal (human insulin: 30 min; lispro: 0 min). Observation parameters were HbA1c, daily and postprandial blood glucose profiles, adverse events, rate of hypoglycemic and hyperglycemic events, number of catheter obstructions, and treatment satisfaction as assessed with an international validated questionnaire. RESULTS: The patients were well controlled with a mean HBA1c of 7.24 +/- 1.0% at baseline. HbA1c decreased in both treatment periods, but it was better during insulin lispro treatment (insulin lispro: 6.8 +/- 0.9%, regular human insulin: 6.9 +/- 1.0%, Friedman's rank-sum test: P < 0.02). In addition, the 1-h and 2-h postprandial rises in blood glucose were significantly lower (P < 0.001 for each meal) with insulin lispro, resulting in smoother daily glucose profiles as compared with regular human insulin. No significant differences were reported for the rate of hypoglycemia (mean +/- SD [median]: insulin lispro 12.4 +/- 13.9 [8], regular human insulin 11.0 +/- 11.2 [8]), for the rate of catheter obstructions (42 events in each treatment arm), and for the number and type of adverse events. No severe case of ketoacidosis was seen during insulin lispro treatment, whereas one case was reported during therapy with regular human insulin. Treatment satisfaction was better when patients were treated with insulin lispro. CONCLUSIONS: Insulin lispro is a suitable and very convenient pump insulin that may result in an improvement of long-term glucose control during CSII treatment. Its safety profile does not differ from that of regular human insulin.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3