Use of a plastic insulin dosage guide to correct blood glucose levels out of the target range and for carbohydrate counting in subjects with type 1 diabetes.

Author:

Kaufman F R1,Halvorson M1,Carpenter S1

Affiliation:

1. Childrens Hospital Los Angeles, Department of Pediatrics, University of Southern California, School of Medicine, California, USA. fkaufman@chla.usc.edu.

Abstract

OBJECTIVE: To improve glycemic control, a hand-held plastic Insulin Dosage Guide was developed to correct blood glucose levels outside of the target range. RESEARCH DESIGN AND METHODS: Protocol 1: Some 40 children (mean age 10.6+/-4.6 years) were randomly assigned for 3 months to use a written-on-paper algorithm or the Insulin Dosage Guide to correct abnormal blood glucose levels. Mean HbA1c and blood glucose levels and time to teach insulin dosage correction were compared. Protocol 2: The Insulin Dosage Guide was used by 83 subjects (mean age 11.4+/-4.3 years) for 1 year, and mean HbA1c levels, blood glucose levels, and number of consecutive high blood glucose values taken before and after the year were compared. Protocol 3: Some 20 patients (mean age 10.1+/-3.7 years) using rapid-acting insulin and 64 patients (mean age 15.9+/-3.6 years) using an insulin pump and rapid-acting insulin used the Insulin Dosage Guide and had mean blood glucose levels, HbA1c, and percentage of blood glucose levels outside of the target range determined. RESULTS: Protocol 1: There was a significant reduction in mean HbA1c (P = 0.04) and blood glucose levels (P = 0.05) and in the time needed to teach how to correct blood glucose values using the Insulin Dosage Guide compared with the paper algorithm. Protocol 2: There was a decrease in mean HbA1c levels (P = 0.0001) and a decrease in the mean number of consecutive blood glucose levels (P = 0.001) over the 1-year time period. Protocol 3: With rapid-acting insulin, there was a significant increase in the percentage of blood glucose levels within the target range (1 month, P = 0.04; at 3 months, P = 0.03). With the insulin pump, there was a high rate (90%) of blood glucose levels in the target range during pump initiation when the Insulin Dosage Guide was used. CONCLUSIONS: This inexpensive hand-held plastic card, which is portable and easy to use, may help patients improve glycemia and successfully manage diabetes.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3