Macrovascular Risk and Diagnostic Criteria for Type 2 Diabetes

Author:

Jesudason David R.1,Dunstan Kerrie1,Leong Darryl1,Wittert Gary A.12

Affiliation:

1. Department of Endocrinology and Metabolism, Royal Adelaide Hospital, Adelaide, Australia

2. Department of Medicine, University of Adelaide, Adelaide, Australia

Abstract

OBJECTIVE—The use of fasting plasma glucose (FPG) level ≥7.0 mmol/l leads to underdiagnosis of type 2 diabetes compared with the oral glucose tolerance test (OGTT). The OGTT is of limited use for population screening. Most of the increase in cardiovascular risk in relation to increasing blood glucose occurs before the threshold at which the diagnosis of type 2 diabetes is made. The aim of this study was to evaluate the use of HbA1c and FPG as predictors of type 2 diabetes and cardiovascular risk and, accordingly, to develop a rational approach to screening for abnormalities of glucose tolerance. RESEARCH DESIGN AND METHODS—OGTT and measurement of HbA1c and FPG levels were performed in 505 subjects screened for type 2 diabetes. Anthropomorphic measurements were obtained. A cardiovascular risk factor questionnaire was completed. RESULTS—The subjects were aged 19–88 years (mean 53.8). The incidence of type 2 diabetes was 10.4% based on the OGTT and 4% based on an FPG level ≥7.0 mmol/l. Using high-performance liquid chromatography (HPLC), HbA1c of <4.7 and ≥6.2% predicted with certainty the absence or presence of type 2 diabetes as defined by the OGTT. The corresponding cutoffs were <5.0 and ≥6.8% for HbA1c (DCA2000 HPLC device; Bayer Diagnostics, Mulgrave, Australia) and <4.7 and ≥6.4 mmol/l for FPG. However, 75–85% of subjects in each case had intermediate values, which were therefore nondiagnostic. Cardiovascular risk increased at least 2.2 times at an HbA1c level ≥6.2% (by HPLC), 1.8–2.2 times at an HbA1c level of 5.6–6.1% (by HPLC), 2 times at an FPG level ≥6.4 mmol/l, and 1.7–1.9 times at an FPG level of 5.6–6.3 mmol/l. CONCLUSIONS—Measurement of FPG and HbA1c levels will diagnose or exclude type 2 diabetes with certainty in a minority (15%) of people. There is a continuous relationship between FPG and HbA1c and cardiovascular risk. Accordingly, we propose that there is a rational basis for using either FPG and HbA1c for purposes of screening and assigning risk. Individuals with an HbA1c level of 5.6–6.1% and an FPG level of 5.6–6.3 mmol/l are at greatest risk for cardiovascular disease and should be targeted for further evaluation. An algorithm outlining a cost-effective approach is presented.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3